| 数据搜索系统,热门电子元器件搜索 |
|
AS73211 数据表(PDF) 24 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS73211 数据表(HTML) 24 Page - OSRAM GmbH |
|
24 / 66 page ![]() Document Feedback AS73211 Functional Description Datasheet • PUBLIC DS000556 • v3-01 • 2018-Feb-07 65 │ 23 2. OSR programming: 80h, start of the measurement as stated in the device’s configuration. Coming from Power Down state activated by OSR:PD = ‚1‘ the AS73211 is active switched on not unti l OSR:SS is set to ‚1‘ (together while or with OSR:DOS = 011b). That means the bit OSR:SS is a direct start condition for the CMD and CONT modes whereas for both SYN modes also the falling edge at pin SYN is necessary for the startup. The programmed measurement mode follows after startup marked by the falling edge of the signal path at pin READY. If the configuration even contains CREG3:SB = ‚1‘ (as the example of Figure 21shows), additionally after startup time TSTARTPD the wake-up time TSTARTSB of 4µs follows before the measurement starts. Figure 21: Principle Start of the M easurement from OSR:PD = ‚1‘ and CREG3:SB = ‚1‘ Figure 21 shows the principle start of the measurement from OSR:PD = ‚1‘ and CREG3:SB = ‚1‘: a) CREG3 p rogramming: bit CREG3:SB = ‚1‘, b) OSR programming: C3h, start of the measurement with prior run of TSTARTPD and TSTARTS. The programmed energy saving option (before or when measurement is started or while the measurement runs) is switched on after the regular end of the measurement and storing of the results within the buffer registe rs. In case of an abortion of the measurement with OSR:SS = ‚0‘ or switching to Configuration state the energy saving option is switched on without saving any results. 7.11 Standby Standby is another option for reducing the power consumption, but compared to Power Down less internal analog components are switched off to be able to get back active in a very short time. The digital part of the AS73211 stays idle, but a full communication via the I²C interface is granted in Configuration state and Measurement state as well. The bit CREG3:SB can only be changed in Configuration mode. The wake-up process is possible in combination with the start condition of the configured Measurement mode. Standby is automatically deactivated by starting the CMD or CONT TSTARTSB MEASUREMENT S CONFIGURATION POWDOWN STATE I²C activity OSR C3h b) CREG3:SB ← ‚1' a) TSTARTPD STANDBY |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |