| 数据搜索系统,热门电子元器件搜索 |
|
AS73211 数据表(PDF) 46 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS73211 数据表(HTML) 46 Page - OSRAM GmbH |
|
46 / 66 page ![]() Document Feedback AS73211 Register Description Datasheet • PUBLIC DS000556 • v3-01 • 2018-Feb-07 65 │ 45 Figure 45: Operational State Register (OSR) ¬ – Address 0h OPERATIONAL STATE REGISTER NAME VALUE [b] OPERATIONAL STATE bit 7 SS 0 (1) Stop of the measurement 1 Start of the measurement (only possible with DOS = MEASUREMENT) bit 6 PD 0 Power Down state switched OFF 1 (2) Power Down state switched ON bit 5 and 4 Reserved (3) bit 3 (4) SW_RES 0 (5) - 1 Software reset bit 2 to 0 Device Operational State (6) (DOS) 00X NOP (no change of DOS) 010 (7) Operational state: CONFIGURATION 011 Operational state: MEASUREMENT 1XX NOP (no change of DOS) (1) Default value after power-on reset, software reset and change into Configuration state. (2) Default value after power-on reset and software reset. (3) The read value is always 00b as well as the recommended write value. (4) Bit 3 (SW_RES) is only active during write access, a read access always returns ‚0‘. (5) Default value after power-on reset and software reset (6) The OSR result of a register read process always returns 010b or 011b for the DOS bits. (7) Default value after power-on-reset, software reset or after mode change from measurement mode to configuration mode. DOS switches the operational state of the AS73211 between configuration and measurement. The configuration state enables the access to the control register bank (Figure 44) and no measurement takes place. The measurement the access to the result registers can only be performed in the measurement state. Then any access to the control register bank (except OSR) is not possible. If the operational state is switched back to the configuration state by DOS = 010b, the control registers keep their values. The measurement result registers are cleared. Any ongoing measurement is stopped immediately. The DOS sequence “NOP” (00Xb or 1XXb) does not change the operational state, but the values of the other written OSR bits are effective. SW_RES = ‚1‘ causes a software reset of the AS73211. A running measurement is stopped immediately and the AS73211 is set to configuration state. All registers are reset to their initial values. The start of a measurement is controlled by the value of bit SS. This bit is only interpreted in the measurement state. The Power Down state is controlled by the value of bit PD. The Power Down takes effect in both operational states: configuration and measurement. If the Power Down state is switched on while the device is in measurement state, the power down is only performed during the breaks between two conversions. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |