| 数据搜索系统,热门电子元器件搜索 |
|
TCS3530 数据表(PDF) 11 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
TCS3530 数据表(HTML) 11 Page - OSRAM GmbH |
|
11 / 106 page ![]() Page 10 Datasheet, Public Document Feedback [v3-00] 2023-Jun-23 TCS3530 − Optical Characteristics Wavelength Accuracy The Channel Center Wavelength and Full-Width-Half-Max Wavelength is measured in-line during filter deposition by means of monitor glasses placed next to the wafers (Test Level 3). Figure 10: Channel Center Wavelength Figure 11: Channel Full Width Half Max Wavelength (FWHM) Parameter Conditions Min Typ Max Unit Test Level X1 Measured in-line with calibrated monochromator using transparent monitor glasses and placed behind a diffuser. 426 436 446 nm 3 X2 584 594 604 Y 545 555 565 Z 435 445 455 HgL 509 519 529 HgH 535 545 555 Parameter Conditions Min Typ Max Unit Test Level X1_low Measured in-line with calibrated monochromator using transparent monitor glasses and placed behind a diffuser. 410 420 430 nm 3 X2_low 538 548 558 Y_low 498 508 518 Z_low 411 421 431 HgL_low 498 508 518 HgH_low 525 535 545 X1_high 455 465 475 X2_high 622 632 642 Y_high 603 613 623 Z_high 466 476 486 HgL_high 521 531 541 HgH_high 547 557 567 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|