19 / 44 page ![]() 2000 Sep 07 19 Philips Semiconductors Preliminary specification Universal Timeslot Interchange SC2000 Table 3. Local Bus Interface Timing — SCbus Mode (2.048 Mbps) Symbol Parameter Min Typ Max Unit t1 SCLKx2* low time 122 ns t2 SCLKx2* high time 122 ns t3 SCLKx2* period 244 ns t4 SCLK low time 244 ns t5 SCLK high time 244 ns t6 SCLK period 488 ns t7 FSYNC* setup to SCLK ↑ 0 ns t8 FSYNC* hold from SCLK ↑ 15 ns t9 SI_CLK ↓delay from SCLKx2*↓ 40 ns t10 SI_CLK ↑delay from SCLKx2*↑ 40 ns t11 SO_CLK ↑delay from SCLK↑ 40 ns t12 SO_CLK ↓delay from SCLK↓ 40 ns t13 SI_FS, SI_MS ↓delay from SCLKx2*↑ 45 ns t14 SI_FS, SI_MS ↑delay from SCLKx2*↑ 45 ns t15 SO_FS, SO_MS ↑delay from SCLK↑ 45 ns t16 SO_FS, SO_MS ↓delay from SCLK↑ 45 ns t17 SO float to valid delay from SCLK ↑ 40 ns t18 SO valid to valid delay from SCLK ↑ 40 ns t19 SO valid to float delay from SCLK ↑ 25 ns t20 SI setup to SCLK ↓(50% sample position) 0 ns t21 SI hold from SCLK ↓(50% sample position) 25 ns t22 SI setup to SCLKx2* ↑(75% sample position) 0 ns t23 SI hold from SCLKx2* ↑(75% sample position) 25 ns t24 SD_[15:0] float to valid delay from SCLK ↑ 35 ns t25 SD_[15:0] valid to valid delay from SCLK ↑ 35 ns t26 SD_[15:0] valid to float delay from SCLK ↑ 25 ns t27 SD_[15:0] setup to SCLK ↓(50% sample) 0 ns t28 SD_[15:0] hold from SCLK ↓(50% sample) 25 ns t29 SD_[15:0] setup to SCLKx2* ↑(75% sample) 0 ns t30 SD_[15:0] hold from SCLKx2* ↑(75% sample) 25 ns t31 TXD setup to SCLK ↑(registered MC) 0 ns t32 TXD hold from SCLK ↑(registered MC) 25 ns t33 MC delay from SCLK ↑ (registered MC) 85 ns t34 MC delay from TXD (passed through MC 80 ns t35 RXD delay from MC 35 ns Notes: 1. Timing measured with 100 pF load on all Local Bus outputs, 200 pF load on all SCbus outputs. 2. MC timing measured with 200 pF, 470 Ωpullup (4.7 K Ω/10). Open collector low to high transitions include 61 ns delay from hi-Z to 2.4 V. 3. SI_CLK, SI_FS and SI_MS shown in ST-BUS framing format. When in PEB conventional framing format SI_CLK, SI_FS and SI_MS have identical timing to SO_CLK, SO_FS and SO_MS. 4. SO shown configured as tri-state driver. 5. SO_MS, SI_MS are free-running multi-frame synchronization signals that occur once every 16 frames. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |