148 / 179 page ![]() 148/179 ST92141 - ANALOG TO DIGITAL CONVERTER (ADC) ANALOG TO DIGITAL CONVERTER (Cont’d) Single and continuous conversion modes are available. Conversion may be triggered by an ex- ternal signal or, internally, by the Multifunction Timer. Conversion Time The maximum conversion time is as follows: 138 * FDF * INTCLK The minimum sample time is: 84 * FDF * INTCLK where FDF is the Frequency Division Factor (refer to the PR bit description in the CCR register). For instance, if PR[2:0] = 100 -> FDF = 8 then the conversion time is: 138 * 8 * INTCLK = 1104 and the sample time is 84 * 8 * INTCLK = 672 INTCLK. A Power-Down programmable bit allows the ADC to be set in low-power idle mode. The ADC’s Interrupt Unit provides two maskable channels (Analog Watchdog and End of Conver- sion) with hardware fixed priority, and up to 7 pro- grammable priority levels. CAUTION: ADC INPUT PIN CONFIGURATION The input Analog channel is selected by using the I/O pin Alternate Function setting (PXC2, PXC1, PXC0 = 1,1,1) as described in the I/O ports sec- tion. The I/O pin configuration of the port connect- ed to the A/D converter is modified in order to pre- vent the analog voltage present on the I/O pin from causing high power dissipation across the input buffer. Deselected analog channels should also be maintained in Alternate function configuration for the same reason. 7.6.2 Functional Description 7.6.2.1 Operating Modes Two operating modes are available: Continuous Mode and Single Mode. To enter one of these modes it is necessary to program the CONT bit of the Control Logic Register. The Continuous Mode is selected when CONT is set, while Single Mode is selected when CONT is reset. Both modes operate in AUTOSCAN configuration, allowing sequential conversion of the input chan- nels. The number of analog inputs to be converted may be set by software, by setting the number of the first channel to be converted into the Control Register (SC2, SC1, SC0 bits). As each conver- sion is completed, the channel number is automat- ically incremented, up to channel 7. For example, if SC2, SC1, SC0 are set to 0,1,1, conversion will proceed from channel 3 to channel 7, whereas, if SC2, SC1, SC0 are set to 1,1,1, only channel 7 will be converted. When the ST bit of the Control Logic Register is set, either by software or by hardware (by an inter- nal or external synchronisation trigger signal), the analog inputs are sequentially converted (from the first selected channel up to channel 7) and the re- sults are stored in the relevant Data Registers. In Single Mode (CONT = “0”), the ST bit is reset by hardware following conversion of channel 7; an End of Conversion (ECV) interrupt request is is- sued and the ADC waits for a new start event. In Continuous Mode (CONT = “1”), a continuous conversion flow is initiated by the start event. When conversion of channel 7 is complete, con- version of channel 's' is initiated (where 's' is spec- ified by the setting of the SC2, SC1 and SC0 bits); this will continue until the ST bit is reset by soft- ware. In all cases, an ECV interrupt is issued each time channel 7 conversion ends. When channel 'i' is converted ('s' <'i' <7), the relat- ed Data Register is reloaded with the new conver- sion result and the previous value is lost. The End of Conversion (ECV) interrupt service routine can be used to save the current values before a new conversion sequence (so as to create signal sam- ple tables in the Register File or in Memory). 7.6.2.2 Triggering and Synchronisation In both modes, conversion may be triggered by in- ternal or external conditions; externally this may be tied to EXTRG, as an Alternate Function input on an I/O port pin, and internally, it may be tied to INTRG, generated by a Multifunction Timer pe- ripheral. Both external and internal events can be separately masked by programming the EXTG/ INTG bits of the Control Logic Register (CLR). The events are internally ORed, thus avoiding potential hardware conflicts. However, the correct proce- dure is to enable only one alternate synchronisa- tion condition at any time. The effect either of these synchronisation modes is to set the ST bit by hardware. This bit is reset, in Single Mode only, at the end of each group of con- versions. In Continuous Mode, all trigger pulses after the first are ignored. The synchronisation sources must be at a logic low level for at least the duration of one INTCLK cycle and, in Single Mode, the period between trig- ger pulses must be greater than the total time re- quired for a group of conversions. If a trigger oc- curs when the ST bit is still set, i.e. when conver- sion is still in progress, it will be ignored. 9 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |