92 / 372 page ![]() M32C/8A Group 9. Clock Generation Circuits Rev.1.00 Jul 15, 2007 Page 75 of 352 REJ09B0385-0100 Figure 9.6 PLC0 Register, PLC1 Register b7 1 0 1 b6 b5 b4 b1 b2 b3 PLL Control Register 0 (1, 2, 5) Symbol PLC0 Address 0026h Bit Symbol Bit Name RW PLC00 After Reset 0001 X010b NOTES: 1. Set the PLC0 register after the PRC0 bit in the PRCR register is set to 1 (write enable). 2. If the PM21 bit in the PM2 register is set to 1 (disables a clock chang), a write to the PLC0 register has no effect. 3. Set bits PLC02 to PLC00 while the PLC07 bit is 0. Bits PLC02 to PLC00 can be written only once. 4. Enter wait mode or stop mode after the CM17 bit is set to 0 (main clock as CPU clock source) and then the PLC07 bit to 0. 5. Set registers PLC0 and PLC1 simultaneously in 16-bit units . b0 Function Programmable counter select bits(3) PLC01 PLC02 The VCO clock is the main clock multiplied by the following variables. b2 b1 b0 0 1 1: Multiply-by-6 1 0 0: Multiply-by-8 Do not set to values other than the above − (b3) − (b4) RW RW RW − (b5) RW Reserved bit Set to 1 Set to 1 − (b6) PLC07 Reserved bit Reserved bit Set to 0 0: PLL stops 1: PLL runs Operation enable bit(4) − RW RW RW NOTES: 1. Set the PLC1 register after the PRC0 bit in the PRCR register is set to 1 (write enable). 2. If the PM21 bit in the PM2 register is set to 1 (disables a clock change), a write to the the PLC1 register has no effect. 3. Set the PLC1 register while the PLC07 bit is 0 (PLL stopped).The PLC1 register can be written only once. 4. Set registers PLC0 and PLC1 simultaneously in 16-bit units. Read as undefined value Reserved bit b7 b6 b5 b4 b1 b2 b3 PLL Control Register 1(1, 2, 3, 4) Bit Symbol Bit Name RW − (b0) RW b0 Function Reserved bit − (b1) RW Reserved bit 0 0 0 0 1 0 PLC12 RW 0: Divide-by-2 1: Divide-by-3 PLL clock division select bit − (b3) RW Reserved bit − (b4) − Read as undefined value Reserved bit − (b7-b5) RW Reserved bits Set to 0 Set to 1 Set to 0 Set to 0 Syambol PLC1 Address 0027h After Reset 000X 0000b |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |