12 / 56 page ![]() ADATE305 Rev. 0 | Page 12 of 56 Parameter Min Typ Max Unit Test Level Conditions/Comments AC SPECIFICATIONS Load active on, unless otherwise noted Dynamic Performance Propagation Delay, Load Active On to Load Active Off; 50%, 90% 7.3 ns CB Toggle RCV, DUTx terminated 50 Ω to GND, IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for IOL and VCOM = −1.25 V for IOH; measured from 50% point of RCVxP − RCVxN to 90% point of final output, repeat for drive low and high Propagation Delay, Load Active Off to Load Active On; 50%, 90% 10.3 ns CB Toggle RCV, DUTx terminated 50 Ω to GND, IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for IOL and VCOM = −1.25 V for IOH; measured from 50% point of RCVxP − RCVxN to 90% point of final output, repeat for drive low and high Propagation Delay Matching 3.0 ns CB Toggle RCV, DUTx terminated 50 Ω to GND, IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for IOL and VCOM = −1.25 V for IOH; active on vs. active off, repeat for drive low and high Load Spike 190 mV CB Toggle RCV, DUTx terminated 50 Ω to GND, IOH = IOL = 0 mA, VH = VL = 0 V, VCOM = +1.25 V for IOL and VCOM = −1.25 V for IOH; repeat for drive low and high Settling Time to 90% 1.9 ns CB Toggle RCV, DUTx terminated 50 Ω to GND, IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for IOL and VCOM = −1.25 V for IOH; measured at 90% of final value PMU FV = force voltage, MV = measure voltage, FI = force current, MI = measure current, FN = force nothing. Table 7. Parameter Min Typ Max Unit Test Level Conditions/Comments FORCE VOL TAGE (FV) Current Range A ±32 mA D Current Range B ±2 mA D Current Range C ±200 μA D Current Range D ±20 μA D Current Range E ±2 μA D Force Input Voltage Range at Output for All Ranges −1.5 +6.0 V D Force Voltage Uncalibrated Accuracy for Range C −100 ±25 +100 mV P PMU enabled, FV, Range C, PE disabled, error measured at calibration points of 0.0 V and 5.0 V Force Voltage Uncalibrated Accuracy for All Ranges ±25 mV CT PMU enabled, FV, PE disabled, error measured at calibration points of 0.0 V and 5.0 V; repeat for each PMU current range Force Voltage Offset Tempco for All Ranges ±25 μV/°C CT Measured at calibration points for each PMU current range Force Voltage Gain Tempco for All Ranges ±10 ppm/°C CT Measured at calibration points for each PMU current range Forced Voltage INL −7 ±2 +7 mV P PMU enabled, FV, Range C, PE disabled, after two-point gain/offset calibration; measured over output range of −1.5 V to +6.0 V Force Voltage Compliance vs. Current Load PMU enabled, FV, PE disabled, force −1.5 V, measure voltage while PMU sinking zero and full-scale current; measure ∆V; force 6.0 V, measure voltage while PMU sourcing zero and full- scale current; measure ∆V; repeat for each PMU current range Range A ±4 mV CT Range B to Range E ±1 mV CT |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |