13 / 56 page ![]() ADATE305 Rev. 0 | Page 13 of 56 Parameter Min Typ Max Unit Test Level Conditions/Comments Current Limit, Source, and Sink Range A 108 140 180 %FS P PMU enabled, FV, PE disabled; sink: force 2.5 V, short DUTx to 6.0 V; source: force 2.5 V, short DUTx to −1.0 V; Range A FS = 32 mA, 108% FS = 35 mA, 180% FS = 58 mA Range B to Range E 120 145 180 %FS P PMU enabled, FV, PE disabled; sink: force 2.5 V, short DUTx to 6.0 V; source: force 2.5 V, short DUTx to −1.0 V; repeat for each PMU current range; example: Range B FS = 2 mA, 120 % FS = 2.4 mA, 180% FS = 3.6 mA DUTGND Voltage Accuracy −7 ±1 +7 mV P Over ±0.1 V range; measured at end points of FV functional range MEASURE CURRENT (MI) VDUTx externally forced to 0.0V, unless otherwise specified, ideal MEASOUT transfer functions: VMEASOUT01 [V] = (IMEASOUT01 × 5/FSR) + 2.5 + VDUTGND I(VMEASOUT01) [A] = (VMEASOUT01 − VDUTGND − 2.5) × FSR/5 Measure Current, Pin DUTx Voltage Range for All Ranges −1.5 +6.0 V D Measure Current Uncalibrated Accuracy Range A ±500 μA CT PMU enabled, FIMI, Range A, PE disabled, error at calibration points −25 mA and +25 mA, error = (I(VMEASOUT01) − IDUTx) Range B −400 ±3.0 +400 μA P PMU enabled, FIMI, Range B, PE disabled, error at calibration points −1.6 mA and +1.6 mA, error = (I(VMEASOUT01) − IDUTx) Range C ± 2.00 μA CT PMU enabled, FIMI, PE disabled, error at calibration points of ±80% FS, error = (I(VMEASOUT01)1 − IDUTx) Range D ±0.30 μA CT PMU enabled, FIMI, PE disabled, error at calibration points of ±80% FS, error = (I(VMEASOUT01) − IDUTx) Range E ±0.08 μA CT PMU enabled, FIMI, PE disabled, error at calibration points of ±80% FS, error = (I(VMEASOUT01) − IDUTx) Measure Current Offset Tempco Range A ±2 μA/°C CT Measured at calibration points Range B ±25 nA/°C CT Measured at calibration points Range C ±5 nA/°C CT Measured at calibration points Range D and Range E ±1 nA/°C CT Measured at calibration points Measure Current Gain Error, Nominal Gain = 1 Range A ±2.5 % CT PMU enabled, FIMI, PE disabled, gain error from calibration points ±80% FS Range B −20 ±2 +20 % P PMU enabled, FIMI, Range B, PE disabled, gain error from calibration points ±1.6 mA Range C to Range E ±4 % CT PMU enabled, FIMI, PE disabled, gain error from calibration points ±80% FS Measure Current Gain Tempco Measured at calibration points Range A ±300 ppm/°C CT Range B to Range E ±50 ppm/°C CT Measure Current INL Range A ±0.05 %FSR CT PMU enabled, FIMI, Range A, PE disabled, after two-point gain/offset calibration, measured over FSR output of −32 mA to +32 mA Range B −0.02 +0.02 %FSR P PMU enabled, FIM,I Range B, PE disabled, after two-point gain/ offset calibration measured over FSR output of −2 mA to +2 mA Range B to Range E ±0.01 %FSR CT PMU enabled, FIMI, PE disabled, after two-point gain/offset calibration; measured over FSR output FVMI DUT Pin Voltage Rejection −0.01 +0.01 %FSR/V P PMU enabled, FVMI, Range B, PE disabled, force −1 V and +5 V into load of 1 mA; measure ∆I reported at MEASOUT01 DUTGND Voltage Accuracy ±2.5 mV CT Over ±0.1 V range; measured at end points of MI functional range |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |