| 数据搜索系统,热门电子元器件搜索 |
|
ATmega16HVB 数据表(PDF) 149 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATmega16HVB 数据表(HTML) 149 Page - ATMEL Corporation |
|
149 / 273 page ![]() 149 8042A–AVR–07/09 ATmega16HVB/32HVB For safe operation the FET driver automatically turns off both the Charge and Discharge FET if the autonomous Battery Protection circuitry (see ”Battery Protection” on page 135) detects an illegal current condition. If such conditions occur, software is not allowed to turn on the FETs until the current condition has normalized. To charge deeply discharged cells the ATmega16HVB/32HVB can be configured to run in Deep Under Voltage Recovery (DUVR) mode. Using chargers with pre-charge current functionality, this allows charging of deeply discharge cells without an additional pre-charge FET. For char- gers without a pre-charge limitation current, an optional pre-charge FET in parallel with a charge FET is supported to be able to charge deeply discharge cells. 25.3 Operation and Usage 25.3.1 Normal Operation In normal operation (DUVRD=1), the FET control is used to enable and disable the Charge FET and Discharge FET. Normally, the FETs are enabled and disabled by SW writing to the FET Control and Status Register (FCSR). However, the autonomous Battery Protection circuitry will if necessary override SW settings to protect the battery cells from too high Charge- or Discharge currents. Note that the CPU is never allowed to enable a FET that is disabled by the battery pro- tection circuitry. The FET control is shown in Figure 25-1 on page 148. Figure 25-2. FET Control module. If Current Protection is activated by the Battery Protection circuitry both the Charge-FET and Discharge FET will be disabled by hardware. When the protection condition disappears the Cur- rent Protection Timer will ensure a hold-off time of 1 second before software can re-enable the external FETs. To turn on the Charge and Discharge FET a minimum VFET supply voltage is required. When the C-FET/D-FET is off with a total cell voltage lower than 6V, SW should not turn on the C- FET/D-FET unless a charger is connected. If the total cell voltage is higher than 6V, SW could turn-on the C-FET or D-FET. Note however, if the FETs are already turned-on, the FET driver can operate in the entire supply operating range of the device. FET Control and Status Register DFE CFE CURRENT_PROTECTION Power-off Mode CHARGE_EN DISCHARGE_EN DUVRD DUVR_OFF Current Protection Timer External_Protection_Input |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |