69 / 81 page ![]() ADT7462 http://onsemi.com 69 Table 58. Register 0x21, Register 0x22, Register 0x23, Register 0x24 — PWM1, PWM2, PWM3 and PWM4 Configuration Registers Bit Name R/W Description [2:0] Spin−Up Timeout R/W These bits set the duration of the fan startup timeout and the timeout for the fan freewheeling test. 000 = No startup timeout 001 = 100 ms 010 = 250 ms 011 = 400 ms 100 = 667 ms 101 = 1 sec 110 = 2 sec 111 = 32 sec 3 SLOW R/W Setting this bit to 1 makes the ramp rate of the enhance acoustics mode four times longer. 4 INV R/W Setting this bit to 0, the PWM outputs are active low. Setting this bit to 1, the PWM outputs are active high (default). [7:5] BHVR R/W These bits determine which temperature channel controls the fans in the automatic fan speed control loop. 000 = Local temperature 001 = Remote 1 temperature 010 = Remote 2 temperature 011 = Remote 3 temperature 100 = Off 101 = Maximum fan speed calculated by the local and Remote 3 temperature channels 110 = Maximum fan speed calculated by all four channels 111 = Manual mode Table 59. Register 0x25 — PWM1, PWM2 Frequency (Note 1) Bit Name R/W Description 0 Min 1 R/W When the ADT7462 is in automatic fan control mode, this bit defines whether PWM1 is off (0% duty cycle) or at minimum PWM1 duty cycle when the controlling temperature is below its TMIN − hysteresis value. 0 = 0% duty cycle below TMIN − hysteresis (default); 1 = minimum PWM1 duty cycle below TMIN − hysteresis. 1 Min 2 R/W When the ADT7462 is in automatic fan control mode, this bit defines whether PWM2 is off (0% duty cycle) or at minimum PWM2 duty cycle when the controlling temperature is below its TMIN − hysteresis value. 0 = 0% duty cycle below TMIN − hysteresis (default); 1 = minimum PWM2 duty cycle below TMIN − hysteresis. [4:2] Low Freq 1 R/W These bits set the frequency of PWM1 when configured in low frequency mode. 000 = 11 Hz 001 = 14.7 Hz 010 = 22.1 Hz 011 = 29.4 Hz 100 = 35.3 Hz (default) 101 = 44.1 Hz 110 = 58.8 Hz 111 = 88.2 Hz [7:5] Low Freq 2 R/W These bits set the frequency of PWM2 when configured in low frequency mode. 000 = 11 Hz 001 = 14.7 Hz 010 = 22.1 Hz 011 = 29.4 Hz 100 = 35.3 Hz (default) 101 = 44.1 Hz 110 = 58.8 Hz 111 = 88.2 Hz 1. POR = 0x90, Lock = Y, SW Reset = Y. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |