| 数据搜索系统,热门电子元器件搜索 |
|
ICS1889 数据表(PDF) 29 Page - Integrated Circuit Systems |
|
|
|||||||||||||||||||||||||||||
ICS1889 数据表(HTML) 29 Page - Integrated Circuit Systems |
|
29 / 35 page ![]() 29 ICS1889 Clocks Transmit Clock Tolerance T# PARAMETER (conditions) MIN TYP MAX UNITS t 1 MDC Minimum High Time 160 —— ns t 2 MDC Minimum Low Time 160 — — ns t 3 MDC Period 400 — — ns t 4 MDC rise to MDIO valid 0 — 300 ns t 5 MDIO Setup to MDC 15 — — ns t 6 MDIO Hold after MDC 0 — — ns t 7 Maximum allowable frequency (50pF Loading) — — 20 MHz |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |