8 / 35 page ![]() 8 ICS1889 Control Register (register 0) The control register is a 16-bit read/write register used to set the basic configuration modes of the ICS1889. It is accessed through the management interface of the MII. Reset (bit 15) default = 0 Setting this bit to a logic 1 will result in the ICS1889 setting all its status and control registers to their default values. During this process the ICS1889 may change internal states and the states of physical links attached to it. While in process, the bit will remain set and no other write commands to the control register will be accepted. The reset process will be completed within 500 ms and the bit will be cleared indicating that the reset process is complete. Loop Back (bit 14) Setting this bit to a logic one causes the ICS1889 to tristate the transmit circuitry from sending data and the receive circuitry from receiving data. The collision detection circuitry is also disabled unless the collision test command bit is set. Data presented to the MII transmit data path is returned to the MII receive data path (see ICS1889 Block Diagram, page 2). Data Rate (bit 13) This bit is permanently set to a logic one indicating that only the 100 Mbps mode is supported. Auto-Negotiation Enable (bit 12) This feature is not available with fiber optic solutions. This bit is permanently set to a logic zero indicating that it is not supported. Power-Down (bit 11) Setting it to logic one will cause the ICS1889 to isolate its transmit data output and its MII interface with the exception of the management interface. The ICS1889 will then enter a power-down mode where only the management interface and logic remain active. Setting this bit to logic zero after it has been set to a logic one will cause the ICS1889 to power-up its logic and then reset all error conditions. It then enables transmit data and the MII interface. This process takes 500 ms to complete. Control Register (register 0) BIT Function Effect when bit = 0 Effect when bit = 1 Access Default 15 Reset No Effect Reset PHY RW/SC 0 14 Loop Back Disable loop back mode Enable loop back mode RW 0 13 Data Rate Always set to a logic one 100 Mpbs operation RO 1 12 Auto-Negotiate Enable No Effect Always set to logic zero RO 0 11 Power-Down Normal Mode Reduced power consumption RW 0 10 Isolate No Effect Isolate PHY from MII RW 0 if PHY Address < >0, 1 if PHY Address=0 9 Restart Auto-Negotitation No Effect Always set to logic zero RO 0 8 Duplex Mode Half Duplex Full Duplex RW 0 7 Collision Test No Effect Enable collision signal test RW 0 6 Reserved RO 0 5 Reserved RO 0 4 Reserved If read, bits 0-6 and bits 9 and 12 will return logic zeroes and bit 13 will return a logic one. RO 0 3 RO 0 2 Reserved Writes to these bits will have no effect. RO 0 1 Reserved RO 0 0 Reserved RO 0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |