| 数据搜索系统,热门电子元器件搜索 |
|
ADE1201 数据表(PDF) 32 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE1201 数据表(HTML) 32 Page - Analog Devices |
|
32 / 40 page ![]() ADE1201 Data Sheet Rev. 0 | Page 32 of 40 BINARY CHANNEL CONTROL REGISTER Address: 0x002, Reset: 0x3610, Name: BIN_CTRL Binary channel and warning controls for decimation and filter modes. Table 20. Bit Descriptions for BIN_CTRL Bits Bit Name Description Reset Access 15 RESERVED Reserved. 0x0 R 14 LOAD_STANDBY_MODE Load Standby Mode. In load standby mode the binary channel monitors the load standby current instead of the ADC voltage values. 0x0 R/W [13:12] WARNC_MODE Comparator Mode. 0x3 R/W 0: hysteretic mode. When the ADC output is greater than the high threshold level of the comparator, the output is set high. The output is set low when the ADC output drops below the low threshold level. 1: midrange mode. When the ADC output is less than the high threshold level and greater than the low threshold level, the comparator output is set high. 10: GT. When the ADC output is greater than the high threshold level, the comparator output is set high. 11: LT mode. When the ADC output is lower than or equal to the high threshold level, the comparator output is set high. [11:10] WARNB_MODE Comparator Mode. 0x1 R/W 0: hysteretic mode. When the ADC output is greater than the high threshold level of the comparator, the output is set high. The output is set low when the ADC output drops below the low threshold level. 1: midrange mode. When the ADC output is less than the high threshold level and greater than the low threshold level, the comparator output is set high. 10: GT mode. When the ADC output is greater than the high threshold level, the comparator output is set high. 11: LT mode. When the ADC output is lower than or equal to the high threshold level, the comparator output is set high. [9:8] WARNA_MODE Comparator Mode. 0x2 R/W 0: hysteretic mode. When the ADC output is greater than the high threshold level of the comparator, the output is set high. The output is set low when the ADC output drops below the low threshold level. 1: midrange mode. When the ADC output is less than the high threshold level and greater than the low threshold level, the comparator output is set high. 10: GT mode. When the ADC output is greater than the high threshold level, the comparator output is set high. 11: LT mode. When the ADC output is lower than or equal to the high threshold level, the comparator output is set high. [7:6] BIN_MODE Comparator Mode. 0x0 R/W 0: hysteretic mode. When the ADC output is greater than the high threshold level of the comparator, the output is set high. The output is set low when the ADC output drops below the low threshold level. 1: midrange mode. When the ADC output is less than the high threshold level and greater than the low threshold level, the comparator output is set high. 10: GT mode. When the ADC output is greater than the high threshold level, the comparator output is set high. 11: LT mode. When the ADC output is lower than or equal to the high threshold level, the comparator output is set high. [5:4] INVALID_MODE Invalid Mode. This bit field selects the value driven onto DOUT1 in invalid mode. 0x1 R/W 00: DOUT1 equals the FORCEVAL bit value. 01: DOUT1 equals the binary filter output. 10: DOUT1 toggles value on entering invalid mode. 11: DOUT1 holds current value. 3 FORCEVAL DOUT1 Value During Invalid Mode. 0x0 R/W |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |