| 数据搜索系统,热门电子元器件搜索 |
|
ADE1201 数据表(PDF) 28 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE1201 数据表(HTML) 28 Page - Analog Devices |
|
28 / 40 page ![]() ADE1201 Data Sheet Rev. 0 | Page 28 of 40 LAYOUT GUIDELINES Figure 20 shows the schematic of the typical ADE1201 application circuit. A 4-layer PCB is recommended for the application circuit. Figure 45 shows the recommended layout to interface one digital input channel given on P0 with one ADE1201. Do not tie the GNDF pins from multiple ADE1201 application circuits together if ac or negative dc inputs are applied. Figure 45. ADE1201 Circuit Board, Top Layer Figure 46 shows a close up of the Figure 45 layout, focusing on the critical areas around the ADE1201. Figure 46. Close Up of the ADE1201 Support Circuitry FERRITE BEAD A ferrite bead is placed on the drain of the FET to prevent parasitics in the application circuit from resonating with the FET at high frequencies (hundreds of MHz). Place a ferrite bead near the drain of the FET (see the yellow Circle 1 labels in Figure 46). DECOUPLING AND GROUND PLANE CONNECTION A low inductance path to the ground plane is required. It is recommended to use multiple vias to lower the inductance and provide multiple connections to the GNDF ground pins, Pin 1 and Pin 10. When placing the decoupling capacitors, ensure that the smaller capacitor, 0.1 µF, is placed as close as possible to the VDDI pin and GNDF pin (Pin 10) to provide a low inductance from the pin to the capacitor, and from the capacitor to ground. Figure 47 and Figure 48 show close ups of the recommended layout around the ADE1201 Pin 1 and Pin 10, which are indicated by the yellow Circle 2 labels in Figure 46. Figure 47. ADE1201 Pin 1 Close Up Figure 48. ADE1201 Pin 10 Close Up Similar rules apply for decoupling on the isolated side for the GND and VDD supplies on Pin 11 and Pin 12 (see the yellow Circle 4 label in Figure 46). Do not tie the GNDF pins from multiple ADE1201 application circuits together if ac or negative dc inputs are applied. ELECTOMAGNETIC INTERFACE (EMI) CAPACITOR High voltage capacitors are recommended to improve emissions and immunity to conducted disturbances. These capacitors must be connected between the two ground planes (GND and GNDF) through multiple vias, as shown in Figure 49 (see the yellow Circle 3 label in Figure 46). Take care to meet the application creepage and clearance requirements because the distance between the ground planes and the copper on the capacitor footprint is lower than the creepage and clearance of the ADE1201. Through-hole capacitors are not recommended. Figure 49. EMI Capacitor |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |