| 数据搜索系统,热门电子元器件搜索 |
|
L99LD21 数据表(PDF) 26 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99LD21 数据表(HTML) 26 Page - STMicroelectronics |
|
26 / 73 page ![]() Functional description L99LD21 26/73 DS11130 Rev 5 The PWM dimming could be achieved in two different ways: • Through direct input, DIN • With integrated PWM generator Dimming with direct input The signal applies to buck1, buck2 or both, depending on DIN mapping bit configuration (see bits <15:14> and bits <13:12> on Table 16: CR#3: Control Register 3). If the control registers are configured accordingly, one (or both) buck converter(s) are activated and directly controlled by DIN pin. The default configuration is set in order to allow direct driving only for buck1, whilst buck2 is turned off. In case of limp home function, the default conditions are applied. PWM control through DIN has to take into account the DIN filter time (tDIN_FT, 32 µs typical) on rising edge to properly set the desired duty cycle. Dimming with integrated PWM generator This function allows modifying the average current on the LEDs by means of a dedicated control register (see bits <23:14> and bits <13:4> on Table 14: CR#1: Control Register 1). This function must be activated setting the right mapping bits configuration inside the control register 3, and in particular, CR#3<15:14> for Buck1 and CR#3<13:12> for Buck2. To set duty cycle, a 10-bit number must be written in the corresponding register, resulting in a 1024 steps of resolution. The duty cycle is determined through the following equation: Where N is the 10-bit number. The PWM frequency is depending on the PWM_CLK input signal with the following equation: Where PWM_LF is the LEDs dimming frequency. If PWM signal fails, an error bit is reported in the STATUS register where PWMCLK fail is located. An internal fallback oscillator is enabled in order to provide a fixed PWM frequency clock signal (FFALLBACK_CLK), whilst no changes is applied on the duty cycle. Once the external PWM is available again and after a read & clear operation on Status Register 2, the internal clock is disabled and PWM operation continues with the external clock (see Figure 14). 4.3 Protections 4.3.1 Temperature warning The device integrates a temperature warning with two thresholds TW1 and TW2 in each buck’s mosfet. If the Tj of the buck mosfet1 or buck mosfet2 rises above TW1 or TW2, the status bit TWxy is set (x = 1 or x = 2, it stands for the buck1 or buck2, y = 1 or y = 2, it stands for the TW1 or TW2) . TWXY bit is set on the status registers: SR#1<4:3> for Buck1 DC % N 1024 ------------- 100 ⋅ = PWM_LF PWM_CLK 1024 ----------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |