Back Button MPZ2012S221A Datasheet HTML 29Page - STMicroelectronics MPZ2012S221A Datasheet HTML 30Page - STMicroelectronics MPZ2012S221A Datasheet HTML 31Page - STMicroelectronics MPZ2012S221A Datasheet HTML 32Page - STMicroelectronics MPZ2012S221A Datasheet HTML 33Page - STMicroelectronics MPZ2012S221A Datasheet HTML 34Page - STMicroelectronics MPZ2012S221A Datasheet HTML 35Page - STMicroelectronics MPZ2012S221A Datasheet HTML 36Page - STMicroelectronics MPZ2012S221A Datasheet HTML 37Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 33 / 56 page
background image
9.2
Switching frequency
A resistor connected to the FSW pin features the selection of the switching frequency (refer to
Section 4.1 Frequency selection table).
Connecting the resistor between the pins FSW and VCC, the internal dithering circuit is turned on (see Figure 3).
The selection of the switching frequency must take into account the minimum on-time of the device (TON MIN, as
indicated in the electrical characteristics table), as described by the following equation:
fSW_max≤ VOUT
TONMIN∙VIN∙η
(26)
The switching frequency affects the selection of the primary inductance as well as the transformer construction.
The efficiency also varies with the switching frequency (see Figure 24 and Figure 26).
9.3
Programmable power-up threshold
The Enable rising threshold is equal to 1.2 V typical (refer to Table 6. Electrical characteristics). The power-up
threshold is adjusted according to the following equation:
VPowerUP=1.2∙ 1+REN1REN2
(27)
Figure 40. Programming power-up threshold
VIN
VIN
EN/CLKIN
AGND
AGND
EP
VIN
GND
L6983I
REN1
REN2
The Enable falling threshold is equal to 1.0 V typical (refer to Table 6. Electrical characteristics). The turn
threshold is obtained according to the following equation:
VPowerDown=1.0∙ 1+REN1REN2
(28)
L6983I
Switching frequency
DS14040 - Rev 1
page 33/56



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com