Specification
NET2270 USB Interface Controller
______________________________________________________________________________
NetChip Technology, Inc., 2003
335 Pioneer Way, Mountain View, California 94041
TEL (650) 526-1490
FAX (650) 526-1494
http://www.netchip.com
Rev 3.6, April 17, 2003
46
In power-sensitive applications, the local CPU can force the NET2270 to enter low-power suspend mode when
disconnected from the USB by writing a 1 to the Suspend Request Interrupt bit. The NET2270 will automatically
wake-up when the peripheral is re-connected (cable plugged in and USB Detect Enable bit set) to the USB. Do not
force suspend mode unless the peripheral is disconnected from the USB. When the NET2270 is connected to the
USB, it is a violation of the USB specification to enter the suspend state unless the upstream port has been idle for
at least 3 milliseconds.
This is the preferred method of suspending the NET2270, since a USB re-connection will automatically cause the
NET2270 to wake-up and set the Resume Interrupt bit.
7.2.2.2 Power-On Standby
The local CPU can prevent the NET2270 from starting its oscillator on power-up by driving a LOW into the CS#
pin while RESET# is asserted (LOW). In this state the NET2270 requires only a small quiescent standby current.
When the peripheral wishes to start the oscillator, it releases the CS# pin and continues to assert RESET# for a
minimum of 2 milliseconds. Note that while the oscillator is stopped, the NET2270 cannot respond to USB
requests, so the oscillator must be allowed to start when the peripheral detects a USB connection event. The local
CPU is responsible for detecting the connection, and ending the standby condition.
This standby technique is appropriate when the device’s power budget does not allow the NET2270 to be active
long enough to shut it down by setting the Suspend Request Interrupt bit.