86 / 90 page

Specification
NET2270 USB Interface Controller
______________________________________________________________________________
NetChip Technology, Inc., 2003
335 Pioneer Way, Mountain View, California 94041
TEL (650) 526-1490
FAX (650) 526-1494
http://www.netchip.com
Rev 3.6, April 17, 2003
86
10.4.7 Local Bus Non-Multiplexed Write
Operating Conditions: VDD: 3.3V ± 5%, TA = 0°C to 70°C, Output Load = 25pF
NAME
DESCRIPTION
MIN
MAX
UNIT
T10
Address setup to end of write enable*
5
ns
T11
Address hold from end of write enable*
0
ns
T12
Write enable width*
5
ns
T13
Data setup to end of write enable*
5
ns
T14
Data hold time from end of write enable*
1
ns
T15A
Recovery Time to next write
55
ns
T15B
Recovery Time to next read
55
ns
* Write enable is the occurrence of both CS# and IOW#.
T11
T11
T12
T10
T13
T15A
T12
T10
T13
T14
T14
A0
A1
D0
D1
0ns
25ns
50ns
LA[4:0]
CS# & IOW#
LD[15:0]