197 / 429 page ![]() 197/429 MULTIFUNCTION TIMER (MFT) MULTIFUNCTION TIMER (Cont’d) 10.4.4 Output Pin Assignment Two external outputs are available when pro- grammed as Alternate Function Outputs of the I/O pins. Two registers Output A Control Register (OACR) and Output B Control Register (OBCR) define the driver for the outputs and the actions to be per- formed. Each of the two output pins can be driven from any of the three possible sources: – Compare Register 0 event logic – Compare Register 1 event logic – Overflow/Underflow event logic. Each of these three sources can cause one of the following four actions on any of the two outputs: – Nop – Set – Reset – Toggle Furthermore an On Chip Event signal can be driv- en by two of the three sources: the Over/Under- flow event and Compare 0 event by programming the CEV bit of the OACR register and the OEV bit of OBCR register respectively. This signal can be used internally to synchronise another on-chip pe- ripheral. Output Waveforms Depending on the programming of OACR and OB- CR, the following example waveforms can be gen- erated on TxOUTA and TxOUTB pins. For a configuration where TxOUTA is driven by the Over/Underflow (OUF) and the Compare 0 event (CM0), and TxOUTB is driven by the Over/Under- flow and Compare 1 event (CM1): OACR is programmed with TxOUTA preset to “0”, OUF sets TxOUTA, CM0 resets TxOUTA and CM1 does not affect the output. OBCR is programmed with TxOUTB preset to “0”, OUF sets TxOUTB, CM1 resets TxOUTB while CM0 does not affect the output. For a configuration where TxOUTA is driven by the Over/Underflow, by Compare 0 and by Compare 1; TxOUTB is driven by both Compare 0 and Com- pare 1. OACR is programmed with TxOUTA pre- set to “0”. OUF toggles Output 0, as do CM0 and CM1. OBCR is programmed with TxOUTB preset to “1”. OUF does not affect the output; CM0 resets TxOUTB and CM1 sets it. OACR = [101100X0] OBCR = [111000X0] T0OUTA T0OUTB OUF COMP1 OUF COMP1 OUF COMP0 OUF COMP0 OACR = [010101X0] OBCR = [100011X1] T0OUTA T0OUTB COMP1 COMP1 OUF OUF COMP0 COMP0 COMP0 COMP0 COMP1 COMP1 9 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |