Back Button L9963E Datasheet HTML 84Page - STMicroelectronics L9963E Datasheet HTML 85Page - STMicroelectronics L9963E Datasheet HTML 86Page - STMicroelectronics L9963E Datasheet HTML 87Page - STMicroelectronics L9963E Datasheet HTML 88Page - STMicroelectronics L9963E Datasheet HTML 89Page - STMicroelectronics L9963E Datasheet HTML 90Page - STMicroelectronics L9963E Datasheet HTML 91Page - STMicroelectronics L9963E Datasheet HTML 92Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 88 / 184 page
background image
Figure 24. Equivalent FSM behavior of the voltage conversion routine
4.12.2.1
On-Demand conversions
To start On-Demand Conversions, the user must set SOC = 1 in the ADCV_CONV register: in case the
Coulomb Counting Routine is enabled, everytime an on-demand voltage conversion is requested by setting
SOC = 1, the actual conversion start is delayed until the first useful current conversion takes place. This
allows a perfect synchronization between voltage and current samples, but might result in a maximum delay
of TCYCLEADC_CUR, that must be taken into account by user SW and added to the recommended TDATA_READY in
Table 38.
Cell Conversion and VBAT Conversion step are always executed
GPIO Conversion is executed only if GPIO_CONV = 1 in the same SPI frame
GPIO Terminal Diagnostics is executed only if GPIO_TERM_CONV = 1 in the same SPI frame
Cell Terminal Diagnostics is executed only if CELL_TERM_CONV = 1 in the same SPI frame
Balance Terminal Diagnostics is executed only if BAL_TERM_CONV = 1 in the same SPI frame
HardWare Self-Check (HWSC) is executed only if HWSC = 1 in the same SPI frame
Once set, SOC stays high until the conversion routine ends (refer to for the routine duration TROUTINE), then
it is internally reset. While SOC is high, any attempt to perform an on-demand conversion will be discarded. A
feedback on the on-demand conversion status can be retrieved via the DUTY_ON flag. Setting any of the optional
bit without setting SOC in the same SPI frame has no effect: conversion will not be started.
The user can select the desired voltage acquisition window (TCYCLEADC) by programming the ADC_FILTER_SOC
fielding the ADCV_CONV register.
L9963E
Voltage conversion routine
DS13636 - Rev 12
page 88/184



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com