| 数据搜索系统,热门电子元器件搜索 |
|
L9963E 数据表(PDF) 95 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9963E 数据表(HTML) 95 Page - STMicroelectronics |
|
95 / 184 page ![]() Operation Skip condition GPIO4 GPIO4_CONFIG != 00 GPIO5 GPIO5_CONFIG != 00 GPIO6 GPIO6_CONFIG != 00 GPIO7 GPIO7_CONFIG != 00 GPIO8 GPIO8_CONFIG != 00 GPIO9 GPIO9_CONFIG != 00 The step duration is fixed: it lasts TCYCLEADC_000 (refer to Table 38). The following failures can be flagged during GPIO conversion step execution, thus causing Configuration Override: • GPIOX_OT: if the converted voltage is lower than the programmed UV/OT threshold (VGPIOAN_OT). • GPIOX_UT: if the converted voltage is higher than the programmed OV/UT threshold (VGPIOAN_UT). • GPIOX_fastchg_OT: if the converted voltage is lower than the programmed fast charge UV/OT threshold (VGPIOAN_OT + VGPIO_FASTCH_OT_DELTA); this function can be masked with a dedicated bit (Gpiox_fastchg_OT_MSK). 4.12.3.4 GPIO terminal diagnostics GPIO terminal diagnostics is the fourth step of the voltage conversion routine. It is optional: • To include it in an On-Demand Conversions, the GPIO_TERM_CONV bit must be set along with the SOC in the same SPI frame. • To specify its periodicity in Cyclic Conversions, the NCYCLE_GPIO_TERM field must be programmed (refer to Section 4.12.4 Operations periodicity). During this step, the GPIO open diagnostic will be performed on all GPIOs configured as analog inputs. Table 63. Operations performed during GPIO terminal diagnostics step Operation Skip condition GPIO1 Open Always GPIO2 Open Always GPIO3 Open GPIO3_CONFIG != 00 GPIO4 Open GPIO4_CONFIG != 00 GPIO5 Open GPIO5_CONFIG != 00 GPIO6 Open GPIO6_CONFIG != 00 GPIO7 Open GPIO7_CONFIG != 00 GPIO8 Open GPIO8_CONFIG != 00 GPIO9 Open GPIO9_CONFIG != 00 The step duration is fixed: it lasts TGPIO_OPEN_SET + TCYCLEADC_000 (refer to Table 38). The following failure can be flagged during GPIO terminal diagnostics step execution, thus causing Configuration Override: • GPIOX_OPEN: if VGPIO < VGPIO_OL while IGPIO_PD_OPEN is applied 4.12.3.5 Cell terminal diagnostics Cell terminal diagnostics is the fifth step of the voltage conversion routine. It is optional and its execution mode depends on the ADC_CROSS_CHECK bit (refer to Cell open wire diagnostic for further information): • To include it in On-Demand Conversions, the CELL_TERM_CONV bit must be set along with the SOC in the same SPI frame. L9963E Voltage conversion routine DS13636 - Rev 12 page 95/184 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |