| 数据搜索系统,热门电子元器件搜索 |
|
L9963E 数据表(PDF) 100 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9963E 数据表(HTML) 100 Page - STMicroelectronics |
|
100 / 184 page ![]() Table 70. NCYCLE counter and optional step periodicity NCYCLE COUNTER (11 bit) 1024 512 256 128 64 32 16 8 4 2 1 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 STEP LIST GPIO X GPIO Term X Cell Term X Bal Term X ADC BIST X Analog Comp X The NCYCLE is an 11 bit counter. Optional steps can be configured (via their NCYCLE_X) to be executed every time a specific bx bit toggles. Once the counter reaches the saturation value (2047), it is designed to roll over. Hence, operation periodicity is not affected and may continue for an arbitrary number of cycles. 4.12.5 Transition between cyclic wake up and normal states Any asynchronous event causing L9963E moving to low power states will have the following effect on the voltage conversion routine: • If the OVR_LATCH is set, it means that a Configuration Override is ongoing or has occurred and the command is ignored. In fact, a Configuration Override cannot be interrupted. Moreover, L9963E is locked in Normal state upon failure detection. Hence, the microcontroller must clear the OVR_LATCH before transitioning to a different state. The microcontroller has a feedback that the command was discarded because: – The FAULTL line is risen in case of Configuration Override thus propagating the fault down to the micro. – The Configuration Override latch is set (OVR_LATCH = 1). • However, if the MCU does not respond within the communication timeout, the device will move to sleep anyway. • If no failure occurred, any ongoing conversion activity can be interrupted by a GO2SLP command. The device will immediately move to a low power state (Sleep, Cyclic Wakeup or Silent Balance). • To determine the next state, the CONF_CYCLIC_EN bit will be evaluated: – In case CONF_CYCLIC_EN = 1 L9963E will move to Cyclic Wakeup state, where the wakeup timer is TCYCLE_SLEEP and the voltage acquisition window (TCYCLEADC) is ADC_FILTER_SLEEP. The TCYCLE_OVF failure is avoided by design, since the ADC_FILTER_SLEEP can be only programmed among the first 4 values listed in Table 38. This makes TROUTINE < TCYCLE_SLEEP by design. – In case CONF_CYCLIC_EN = 0 L9963E will move to Sleep or Silent Bal state depending on slp_bal_conf. The dual case is represented by the Cyclic Wakeup → Normal transition. During cyclic wake up, a wake up condition may occur: • If the wake up condition does not involve any Configuration Override (e.g. Microcontroller sent a wake up frame or FAULTH was interpreted ‘high’), then L9963E will move to Normal state and the cyclic activity will continue, since CONF_CYCLIC_EN is still ‘1’. • In case an internal failure is detected during the routine execution, the internal wakeup condition will move L9963E to Normal, while Configuration Override takes place. L9963E Voltage conversion routine DS13636 - Rev 12 page 100/184 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |