| 数据搜索系统,热门电子元器件搜索 |
|
EV5424-R-00A 数据表(PDF) 19 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
EV5424-R-00A 数据表(HTML) 19 Page - Monolithic Power Systems |
|
19 / 44 page ![]() MP5424 – 5V POWER MANAGEMENT IC WITH I2C AND MTP MP5424 Rev. 1.0 MonolithicPower.com 19 12/6/2021 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2021 MPS. All Rights Reserved. VINx DC/DC Converter, LDO, and LSWO Output Time Slot Number 1 2 3 13 Time Slot RSTO RSTO_DELAY No Supply 0 PWRON 14 15 Time Slot Figure 5: Start-Up Sequence Buck Regulators, LDOs, and Load Switch On The MP5424 provides a configurable start-up sequence. See the MTP E-Fuse Configuration Table on page 26 for details on which bits set the time slot number for each channel. Shutdown Factor The PMIC shutdown factors are PWRON_OFF and EN1. They are described below. PWRON_OFF If the PWRON pin is pulled low (PWRON_MODE = 0) or if there is a falling edge on PWRON (PWRON_MODE = 1), then the PMIC enters the shutdown sequence. See the PWRON Functions section on page 21 for more details. EN1 If the EN1 function is enabled, and EN1 is pulled low (EN1_INV defines EN1 as active high) or EN1 is pulled high (EN1_INV defines EN1 as active low), then the power rails controlled by EN1 enter the shutdown sequence. See the EN1 Functions section on page 22 for more details. Shutdown Sequence There are 16 selectable time slots for the shutdown sequence. All of the DC/DC converters, LDOs, and load switch can be configured between 0 and 15 time slots by the MTP e-fuse. The delay time between each time slot can be adjusted via the MTP TIME_SLOT bits. The time does not change with fSW. RSTO is pulled low prior to when the DC/DC converters, LDOs, and load switch turn off. The DC/DC converter and LDO shutdown sequences are set by POWER_OFF_SLOT_NO and POWER_OFF_SLOT_MODE. See the MTP E- Fuse Configuration Table on page 26 for more details. VIN PWRON DC/DC, LDO, and LSWO Output 15 14 13 2 1 0 Time_ SLOT RSTO Power-Off Sequence No Supply UVLO Power Off Time_ SLOT Time Slot Number Figure 6: Shutdown Sequence (PWRON_MODE = 0) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |