| 数据搜索系统,热门电子元器件搜索 |
|
EV5424-R-00A 数据表(PDF) 36 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
EV5424-R-00A 数据表(HTML) 36 Page - Monolithic Power Systems |
|
36 / 44 page ![]() MP5424 – 5V POWER MANAGEMENT IC WITH I2C AND MTP PRELIMINARY SPECIFICATIONS SUBJECT TO CHANGE MP5424 Rev. 0.81 MonolithicPower.com 36 12/6/2021 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. Preliminary Specifications Subject to Change © 2021 MPS. All Rights Reserved. Most of the register bits share the same description as the MTP e-fuse configuration table on page 26. Table 2 shows the descriptions of the I2C register bits that are different from the MTP register bits. The I2C register's default values are determined by the MTP table. The I2C register can be reset to the hard-coded default values under two conditions: 1. There is a CRC error while loading the MTP. 2. The MTP page is set to 0. Thermal shutdown does not reset the I2C register. Table 2: I2C Register Descriptions Name Bits Default Description ENTER_MTP_ MODE D[7] 0 Set ENTER_MTP_MODE to 1 to enter pre-MTP configure mode. After MTP configuration is complete, ENTER_MTP_MODE resets automatically to 0. PROGRAM_ MTP D[6] 0 If PROGRAM_MTP is set 1, then the PMIC executes an MTP configure action . After MTP configuration is complete, PROGRAM_MTP resets automatically to 0. PGx D[X] 0 PG indicator for the buck converters and LDOs. If VOUT exceeds 90% of the VREF, then PGx = 1. If VOUT drops below 80% of VREF, then PGx = 0. During I2C-controlled dynamic voltage scaling, the PG deglitch timer blanks the possible PG glitch. These PG bits change dynamically to indicate the power good of each buck’s and each LDO’s status. OTWARNING D[7] 0 Die temperature early warning bit. If OTWARNING is high, this indicates that the die temperature has exceeded 120°C. OTWARNING latches once it is triggered. Write 1 to OTWARNING to clear it. OTEMPP D[6] 0 Over-temperature (OT) indicator. If OTEMPP is high, this indicates that thermal shutdown has been triggered. OTEMPP latches once it is triggered. Write 1 to OTEMPP to clear it. VENDOR ID D[7:4] 1000 Vendor identification. CHECKSUM FLAG D[4] 0 1: The current MTP page has a CRC or checksum error 0: The current MTP data passes the CRC test CURRENT MTP PAGE INDEX D[1:0] 00 CURRENT MTP PAGE INDEX stores the current MTP page index information. The IC cannot access the MTP while D[1:0] = 10b. The MP5424 MTP can only be configured two times. 00: Default page; two other pages can be used 01: First page 10: Second page 11: Reserved |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |