34 / 109 page ![]() ST7263 34/109 WATCHDOG TIMER (Cont’d) 5.3.3 Functional Description The counter value stored in the CR register (bits T6:T0), is decremented every 49,152 machine cy- cles, and the length of the timeout period can be programmed by the user in 64 increments. If the watchdog is activated (the WDGA bit is set) and when the 7-bit timer (bits T6:T0) rolls over from 40h to 3Fh (T6 becomes cleared), it initiates a reset cycle pulling low the reset pin for typically 500ns. The application program must write in the CR reg- ister at regular intervals during normal operation to prevent an MCU reset. The value to be stored in the CR register must be between FFh and C0h (see Table 14 . Watchdog Timing (fCPU = 8 MHz)): – The WDGA bit is set (watchdog enabled) – The T6 bit is set to prevent generating an imme- diate reset – The T5:T0 bits contain the number of increments which represents the time delay before the watchdog produces a reset. Table 14. Watchdog Timing (fCPU = 8 MHz) Notes: Following a reset, the watchdog is disa- bled. Once activated it cannot be disabled, except by a reset. The T6 bit can be used to generate a software re- set (the WDGA bit is set and the T6 bit is cleared). 5.3.3.1 Using Halt Mode with the WDG The HALT instruction stops the oscillator. When the oscillator is stopped, the WDG stops counting and is no longer able to generate a reset until the microcontroller receives an external interrupt or a reset. If an external interrupt is received, the WDG re- starts counting after 4096 CPU clocks. If a reset is generated, the WDG is disabled (reset state). Recommendations – Make sure that an external event is available to wake up the microcontroller from Halt mode. – Before executing the HALT instruction, refresh the WDG counter, to avoid an unexpected WDG reset immediately after waking up the microcon- troller. – When using an external interrupt to wake up the microcontroller, reinitialize the corresponding I/O as “Input Pull-up with Interrupt” before executing the HALT instruction. The main reason for this is that the I/O may be wrongly configured due to ex- ternal interference or by an unforeseen logical condition. – For the same reason, reinitialize the level sensi- tiveness of each external interrupt as a precau- tionary measure. – The opcode for the HALT instruction is 0x8E. To avoid an unexpected HALT instruction due to a program counter failure, it is advised to clear all occurrences of the data value 0x8E from memo- ry. For example, avoid defining a constant in ROM with the value 0x8E. – As the HALT instruction clears the I bit in the CC register to allow interrupts, the user may choose to clear all pending interrupt bits before execut- ing the HALT instruction. This avoids entering other peripheral interrupt routines after executing the external interrupt routine corresponding to the wake-up event (reset or external interrupt). 5.3.4 Interrupts None. 5.3.5 Register Description CONTROL REGISTER (CR) Read /Write Reset Value: 0111 1111 (7F h) Bit 7 = WDGA Activation bit. This bit is set by software and only cleared by hardware after a reset. When WDGA = 1, the watchdog can generate a reset. 0: Watchdog disabled 1: Watchdog enabled Bit 6:0 = T[6:0] 7-bit timer (MSB to LSB). These bits contain the decremented value. A reset is produced when it rolls over from 40h to 3Fh (T6 becomes cleared). CR Register initial value WDG timeout period (ms) Max FFh 393.216 Min C0h 6.144 70 WDGA T6 T5 T4 T3 T2 T1 T0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |