| 数据搜索系统,热门电子元器件搜索 |
|
ADE7166 数据表(PDF) 58 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7166 数据表(HTML) 58 Page - Analog Devices |
|
58 / 148 page ![]() ADE75xx/ADE71xx Preliminary Technical Data Rev. PrE | Page 58 of 148 0xDB) is set, the 8052 core has a pending ADE interrupt. The ADE interrupt stays active until the CYCEND status bit is cleared—see Energy measurement interrupts section. Another calibration cycle will start as soon as the CYCEND flag is set. If the LWATTHR register is not read before a new CYCEND flag is set, the LWATTHR register will be overwritten by a new value. When a new half line cycles is written in LINECYC register, the LWATTHR register is reset and a new accumulation start at the next zero-crossing. The number of half line cycles is then counted until LINCYC is reached . This implementation provides a valid measurement at the first CYCEND interrupt after writing to the LINCYC register – see Figure 43. The line active energy accumulation uses the same signal path as the active energy accumulation. The LSB size of these two registers is equivalent. LINECYC VALUE CYCEND IRQ LWATTHR REGISTER Figure 43. Energy Accumulation when LINECYC changed From Equations 13 and 18, E(t) = ∫ ∫ ⎪ ⎪ ⎪ ⎭ ⎪⎪ ⎪ ⎬ ⎫ ⎪ ⎪ ⎪ ⎩ ⎪⎪ ⎪ ⎨ ⎧ ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ + − nT nT f VI dt VI 0 2 0 cos 9 . 8 1 (2πft)dt (20) where: n is an integer. T is the line cycle period. Since the sinusoidal component is integrated over an integer number of line cycles, its value is always 0. Therefore, E = ∫ nT VIdt 0 + 0 (21) E(t) = VInT (22) WDIV[7:0] WATTOS[15:0] WGAIN[11:0] LPF1 + + LWATTHR [23:0] ACCUMULATE ACTIVE ENERGY IN INTERNAL REGISTER AND UPDATE THE LWATTHR REGISTER AT THE END OF LINCYC HALF LINE CYCLES OUTPUT FROM LPF2 FROM VOLTAGE CHANNEL ADC 23 0 LINCYC [15:0] 48 0 % ZERO CROSS DETECTION CALIBRATION CONTROL TO DIGITAL TO FREQUENCY CONVERTER Figure 44. Line Cycle Active Energy Accumulation Note that in this mode, the 16-bit LINCYC register can hold a maximum value of 65,535. In other words, the line energy accumulation mode can be used to accumulate active energy for a maximum duration over 65,535 half line cycles. At 60 Hz line frequency, it translates to a total duration of 65,535/120 Hz = 546 seconds. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |