| 数据搜索系统,热门电子元器件搜索 |
|
ADE7166 数据表(PDF) 68 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7166 数据表(HTML) 68 Page - Analog Devices |
|
68 / 148 page ![]() ADE75xx/ADE71xx Preliminary Technical Data Rev. PrE | Page 68 of 148 TEMPERATURE, BATTERY AND EXTERNAL VOLTAGE MEASUREMENTS The ADE75XX/ADE71XX includes temperature measurements as well as battery and an external voltage measurements. These measurements enable many forms of compensation. The temperature measurements can be used to compensate external circuitry. The RTC can be calibrated over temperature to ensure that it doesn’t drift. External voltage measurements allow the VDCIN voltage to be monitored, which is especially useful if the VDCIN voltage tracks the bulk voltage. Battery measurements allow low battery detection to be performed. All ADC measurements are configured through the SFR detailed in Table 45. The temperature, battery and external voltage measurements can be configured to still be functional in PSM1 and PSM2. This is done bit setting bit RTCEN in the RTC Configuration SFR (TIMECON, 0xA1). Maintaining the temperature measurement active ensures that it is not necessary to wait for the temperature measurement to settle before using it for compensation. Table 45. Temperature, Battery and External voltage measurement SFRs SFR address (hex) R/W Name Description 0xF9 R/W STRBPER Strobing period configuration 0xF3 R/W DIFFPROG Temperature and supply Delta configuration 0xD8 R/W ADCGO ADC start configuration 0xFA R/W BATVTH Battery threshold configuration 0xEF R/W VDCINADC VDCIN ADC value 0xDF R/W BATADC Battery ADC value 0xD7 R/W TEMPADC Temperature ADC value Table 46. Peripheral ADC Strobe Period SFR (STRBPER, 0xF9) Note: The strobing option only work when the RTCEN bit in RTC Configuration SFR (TIMECON, 0xA1) is set. Bit Location Bit Mnemonic Default Value Description 7-6 Reserved - Reserved Period for background external voltage measurements VDCIN_PERIOD[1:0] 0 0 No VDCIN measurement 0 1 8 minutes 1 0 2 minutes 5-4 VDCIN_PERIOD[1:0] 0 1 1 1 minute Period for background battery level measurements BATT_PERIOD[1:0] 0 0 No Battery measurement 0 1 16 minutes 1 0 4 minutes 3-2 BATT_PERIOD[1:0] 0 1 1 1 minute Period for background temperature measurements TEMP_PERIOD[1:0] 0 0 No Temperature measurements 1-0 TEMP_PERIOD[1:0] 0 0 1 8 minutes |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |