| 数据搜索系统,热门电子元器件搜索 |
|
TLK6002 数据表(PDF) 41 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TLK6002 数据表(HTML) 41 Page - Texas Instruments |
|
41 / 96 page ![]() 32"1's" 0 1 Pu1 PA4 PA0 D15 D0 1 0 0 Idle 1 Start Read Code PHY Addr Turn Around Data REG Addr RA4 RA0 Preamble MDC MDIO 32 "1's" 0 1 1 PA[4:0] D15 D0 0 1 0 Idle 1 Start Write Code PHY Addr Turn Around Data REG Addr RA4 RA0 Preamble MDC MDIO TLK6002 www.ti.com SLLSE34 – MAY 2010 Table 2-10. MDIO Related Signals SIGNAL TYPE DESCRIPTION MDC LVCMOS Management Interface Clock. This clock is used to sample the MDIO signal. 1.5V/1.8V Input VDDO3 MDIO LVCMOS Management Interface Data. Bidirectional data line for MDIO Port is sampled on the rising edge of MDC. 1.5V/1.8V THIS SIGNAL MUST BE EXTERNALLY PULLED UP TO VDDO3. Consult IEEE802.3 Clause 22 for an appropriate Input/OutputVDDO3 resistance value. PRTAD[4:0] LVCMOS Port Address. Used to select the Port ID in Clause 22 MDIO mode. 1.5V/1.8V PRTAD[4:1] selects a block of two sequential Clause 22 port addresses. Each channel is implemented as a different port Input address, and can be accessed by setting the appropriate port address field within the Clause 22 MDIO transaction. VDDO2/ VDDO1/ VDDO1/ VDDO1/ PRTAD[0] is not used functionally, but is needed for device testability with other devices in the family of products. VDDO1 Channel A responds to port address 0 within the block of two port addresses. Channel B responds to port address 1 within the block of two port addresses. It is possible for 16 TLK6002 devices to logically share an MDIO bus. In Clause 22, the top 4 control pins PRTAD[4:1] determine the device port address. In this mode the 2 individual channels in TLK6002 are classified as 2 different ports. So for any PRTAD[4:1] value there will be 2 ports per TLK6002. TLK6002 will respond if the 4 MSB's of PHY address field on MDIO protocol (PA[4:1]) matches PRTAD[4:1]. The LSB of PHY address field (PA[0]) will determine which channel/port within TLK6002 to respond to. If PA[0] = 1b0, TLK6002 Channel A will respond. If PA[0] = 1b1, TLK6002 Channel B will respond. Write transactions which address an invalid register or device or a read only register will be ignored. Read transactions which address an invalid register will return a 0. MDIO Protocol Timing: The Clause 22 timing required to read from the internal registers is shown in Figure 2-9. The Clause 22 timing required to write to the internal registers is shown in Figure 2-10. (1) Note that the 1 in the Turn Around section is externally pulled up, and driven to Z by TLK6002. Figure 2-15. CL22 – Management Interface Read Timing Figure 2-16. CL22 – Management Interface Write Timing Copyright © 2010, Texas Instruments Incorporated Description 41 Submit Documentation Feedback Product Folder Link(s): TLK6002 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |