| 数据搜索系统,热门电子元器件搜索 |
|
MSP430F2012IN 数据表(PDF) 42 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
MSP430F2012IN 数据表(HTML) 42 Page - Texas Instruments |
|
42 / 91 page ![]() MSP430F20x3 MSP430F20x2 MSP430F20x1 SLAS491G – AUGUST 2005 – REVISED APRIL 2011 www.ti.com 10-Bit ADC, Linearity Parameters (MSP430F20x2) over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT EI Integral linearity error 2.2 V/3 V ±1 LSB ED Differential linearity error 2.2 V/3 V ±1 LSB EO Offset error Source impedance RS < 100 Ω 2.2 V/3 V ±1 LSB EG Gain error 2.2 V/3 V ±1.1 ±2 LSB ET Total unadjusted error 2.2 V/3 V ±2 ±5 LSB 10-Bit ADC, Temperature Sensor and Built-In VMID (MSP430F20x2) (1) over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT 2.2 V 40 120 Temperature sensor supply REFON = 0, INCHx = 0Ah, ISENSOR µA current(1) TA = 25°C 3 V 60 160 TCSENSOR ADC10ON = 1, INCHx = 0Ah(2) 2.2 V/3 V 3.44 3.55 3.66 mV/ °C VOffset,Sensor Sensor offset voltage ADC10ON = 1, INCHx = 0Ah(2) -100 100 mV Temperature sensor voltage at 1265 1365 1465 TA = 105°C (T version only) Temperature sensor voltage at 1195 1295 1395 TA = 85°C VSENSOR Sensor output voltage(3) 2.2 V/3 V mV Temperature sensor voltage at 985 1085 1185 TA = 25°C Temperature sensor voltage at 895 995 1095 TA = 0°C Sample time required if ADC10ON = 1, INCHx = 0Ah, tSENSOR(sample) 2.2 V/3 V 30 µs channel 10 is selected(4) Error of conversion result ≤ 1 LSB 2.2 V N/A Current into divider at IVMID ADC10ON = 1, INCHx = 0Bh µA channel 11(4) 3 V N/A 2.2 V 1.06 1.1 1.14 ADC10ON = 1, INCHx = 0Bh, VMID VCC divider at channel 11 V VMID ≈ 0.5 × VCC 3 V 1.46 1.5 1.54 2.2 V 1400 Sample time required if ADC10ON = 1, INCHx = 0Bh, tVMID(sample) ns channel 11 is selected(5) Error of conversion result ≤ 1 LSB 3 V 1220 (1) The sensor current ISENSOR is consumed if (ADC10ON = 1 and REFON = 1), or (ADC10ON = 1 and INCH = 0Ah and sample signal is high).When REFON = 1, ISENSOR is included in IREF+.When REFON = 0, ISENSOR applies during conversion of the temperature sensor input (INCH = 0Ah). (2) The following formula can be used to calculate the temperature sensor output voltage: VSensor,typ = TCSensor ( 273 + T [°C] ) + VOffset,sensor [mV] or VSensor,typ = TCSensor T [°C] + VSensor(TA = 0°C) [mV] (3) Results based on characterization and/or production test, not TCSensor or VOffset,sensor. (4) No additional current is needed. The VMID is used during sampling. (5) The on time, tVMID(on), is included in the sampling time, tVMID(sample); no additional on time is needed. 42 Copyright © 2005–2011, Texas Instruments Incorporated |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |