| 数据搜索系统,热门电子元器件搜索 |
|
300-R010-45G 数据表(PDF) 27 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
300-R010-45G 数据表(HTML) 27 Page - Magnetrol International, Inc. |
|
27 / 36 page ![]() 27 IMPLEMENTATION This protocol guide explains the operation of the Modbus protocol per Modicon document PI-MBUS-300 Rev J. The Magnetrol implementation of the Modbus protocol pro- vides a standard form of digital communications. An effort has been made to parallel current implementations to the greatest extent possible, so that Magnetrol products com- municate with existing Modbus masters. Check compatibility carefully to ensure that the Model 300/301 is configured for the data format expected by the host computer. Exceptions made because of the unique requirements of the Magnetrol installation have been noted. This is no guarantee, however, that the interpretation made here will be the same as that followed by the Modbus master. The Magnetrol implementation of the Modbus protocol pro- vides for the passing of measured and calculated variables, configuration information, and diagnostics in data registers. Data is sent in these registers as floating point values, integer values, numeric codes related to configuration lists, status summary words (packed bits), or individual flags (single bits). One master and up to 31 units may be multi-dropped on a single RS-485 communication bus. The Modbus functions implemented in Model 300/301 are listed in Table 3. CONFIGURATION The Modbus port on the Model 300/301 must be configured to establish communications. The keypad allows the user to set the Magnetrol Modbus port to match the Modbus mas- ter. See page 24 for configuration instructions. Magnetrol addresses provide unique identification for the host. This address may range from 1 to 247 and must be unique. Each Model 300/301 only responds when a query has been sent to its unique address by the host. Magnetrol units support the Remote Terminal Unit (RTU) mode of transmission. RTU provides improved error detec- tion capabilities and higher throughput than the ASCII mode. The RS-485 port must be configured for a transmission speed (baud rate). Allowable values are 1200, 2400, 4800, or 9600 bits per second. Function Function Information Type MODBUS Code Nomenclature 01 Read 1-bit coils Read coil status 02 Read 1-bit coils Read input status 03 Read 16-bit register/integer Read holding registers 04 Read 16-bit register/integer Read input registers 05 Write 16-bit register/coils Force single coil 06 Write 16-bit register Preset single register 15 Write 16-bit register/coils Force multiple coils 16 Write 16-bit register Preset multiple registers Exception: Because the Model 300/301 does not distinguish between inputs and outputs, function codes 01 and 02 (as they apply to bits) and function codes 03 and 04 (as they apply to numeric values) refer to the same data registers. Table 3 Modbus Functions MODBUS PROTOCOL |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |