| 数据搜索系统,热门电子元器件搜索 |
|
300-R010-45G 数据表(PDF) 5 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
300-R010-45G 数据表(HTML) 5 Page - Magnetrol International, Inc. |
|
5 / 36 page ![]() TRANSDUCER MOUNTING 5 CAUTION: Please read the entire installation section carefully prior to starting installation. Also read the Measurement Range Calculations section on pages 3-4 to make sure that you have selected the proper level system for your application. CAUTION: If equipment is used in a manner not specified by manufacturer, protection provided by equipment may be impaired. GENERAL GUIDELINES The unit can be provided as an integral mount Model 300 with the transducer connected to the transmitter housing, or as a remote mount Model 301 with the transmitter mounted as far as 500' (152 m) away from the transducer. Both the transducer and the transmitter are approved for Class I, Division 1, Groups B, C, & D areas. TRANSDUCER MOUNTING LOCATION Proper mounting of the ultrasonic transducer is very critical to the operation of any non-contact ultrasonic application. Both the accuracy and the reliability of the Model 300/301 can be adversely affected if the transducer is mounted improperly. This section must be followed carefully to make sure that the optimum mounting location is chosen, and that proper mounting techniques are used for the transducer. Several factors should be considered when selecting the transducer location: • Inherent dead band of the transducer • Standpipes • Application difficulties (foam, turbulence, vapors) • Ultrasonic beam angle TRANSDUCER DEAD BAND The transducer must be mounted directly over the liquid sur- face, as shown in Figure 1. Non-contact ultrasonic instru- ments require a “dead band” or “blind space” between the face of the transducer and the maximum liquid level. The minimum dead band for the Model 300/301 is 18" (457 mm). This dead band should be taken into consideration when mounting the transducer. If the level must be measured all the way to the top of the tank, the transducer should be mounted in a standpipe as shown in Figures 2 and 3. STANDPIPES In applications where the material level may come into the dead band, the transducer must be mounted in a standpipe. The diameter of the standpipe should be at least 8" (203 mm); and its length should be limited to 11" (279 mm) from transducer face. Refer to Figure 2. APPLICATION DIFFICULTIES Typically the liquid surface is most turbulent at the fill point. Foam on the other hand, is most likely to accumulate at the opposite end of the fill. Since foam and turbulence can both create difficulties in reflecting a strong ultrasonic signal back into the transducer, it is best to pick a mounting location away from these areas in the vessel. Avoid installing the transducer in tank top openings that exhaust heated air or vapors. The boundaries between the vapors and the outside air often represent acoustic imped- ance gradients that can cause troublesome sound reflec- tions. In those installations, the transducer should be mount- ed well away from the opening inside the tank, or in a stand- pipe as illustrated in Figures 2 and 3. Model 300 Air Liquid Dead band 18" minimum (457 mm) Flange Maximum span 28.5' (8.7 m) Figure 1 Typical Transducer Mounting 8" (203) Minimum I.D. 2" NPT Transducer This end welded or flanged Stand pipe Maximum 11" (279 mm) or less Figure 2 Transducer Mounting in Standpipe Figure 3 Transducer Mounting for Tanks with Exhaust |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |