| 数据搜索系统,热门电子元器件搜索 |
|
300-R010-45G 数据表(PDF) 17 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
300-R010-45G 数据表(HTML) 17 Page - Magnetrol International, Inc. |
|
17 / 36 page ![]() This menu is used to select the measurement units and con- figure the system to measure Volume & Level. Refer to page 15 for Level Only applications or page 20 for Flow & Level applications. Following is a step-by-step procedure for using the Volume & Level menu. It is assumed that you are starting from the RUN mode. SOFTWARE CONFIGURATION cont. 17 SYSTEM CONFIGURATION MENU—VOLUME AND LEVEL System Configuration Menu (Volume and Level) Display Keystroke Comment and/or Additional Keystrokes Magnetrol Int’l Press ENT At start up, the unit is in the run mode displaying Magnetrol Int’l. Pressing ENT xxxx units allows you to enter the main menu. Measured Values Press Allows you to enter the System Config menu. ENT to Select System Config Press ENT Enters the first display (Level Units) of System Config menu. Level Units If inches are the desired Level Units press to continue to the next item. To Inches Press ENT or change units, press ENT and to select Feet, Centimeters, or Meters. Press ENT to select desired Level Units. Enter Password Enter Valid Password Entering a valid password and pressing ENT sets your unit selection and (if units changed) (factory default is 300) continues on to the next item. Mode Setup Press ENT Then press then ENT to change to Volume and Level mode. Level Only Volume Units If cubic feet are the desired Volume Units, press to continue to the next item. Cubic Feet Press ENT or To change units, press ENT and to select cubic inches, gallons, milliliters, or liters. Press ENT to select desired Volume Units. Press ENT, , then ENT to change present setting. You may select Rectangular, Vessel Type Press ENT or Horiz/Flat, Horiz/Ellip, Horiz/Sphere, Spherical, Verti/Flat, Verti/Ellip, Verti/Sphere, Rectangular Verti/Conical or Custom Table (Refer to Figure 12 for Custom Table). If the present setting is correct (Rectangular), press ENT, input vessel dimensions, and then press to continue to next selection. Radius= The values requested may vary depending on the type of vessel selected. Refer xxxx units Enter value and press ENT to vessel drawing for proper dimensions. (Vessel Dependent) Width= The values requested may vary depending on the type of vessel selected. Refer xxxx units Enter value and press ENT to vessel drawing for proper dimensions. (Vessel Dependent) Length= The values requested may vary depending on the type of vessel selected. Refer xxxx units Enter value and press ENT to vessel drawing for proper dimensions. (Vessel Dependent) Range Setting Press ENT or Press ENT to change the range setting. If setting is correct, press to continue xxxx units to Span Settings. NOTE: It is recommended to use Manual Set (as opposed to Auto Set) when changing the range or span settings. Press ENT to manually set the range setting. An will appear in the bottom line Manual Set Press ENT or of the display. This allows you to change the range value. Measure the distance xxxx units from the face of the transducer to the maximum distance to be measured. Enter value and press ENT. If Auto Set is preferred press . The liquid surface must be at the maximum distance to be measured. Check to Auto Set (If chosen) Press ENT or see that the distance being displayed is correct. When you press the ENT key, xxxx units that distance will be set as your range and the program will continue on to the next selection. To continue without making changes press . NOTE: The span value is automatically set ONLY when the entered range value has decreased from its previous value. Span Setting Value shown will be 18 inches less than the range setting. This is the maximum xxxx units Press ENT or span value available. To reduce the span press ENT. If the present setting is correct press to continue to Previous Menu. Manual Set Press ENT to manually set the span setting. Measure the distance from the xxxx units Press ENT or maximum range that was set to the highest point to be measured. Enter value and press ENT. If Auto Set is preferred press . The liquid surface must be at the highest level to be measured. Check to see Auto Set (If chosen) Press ENT or that the level being displayed is correct. When you press the ENT key, that xxxx units measurement will be set as your span and the program will continue on to the next selection. To continue without changes press . Previous Menu Press ENT Pressing the ENT key will set all values and return to System Config. Press DEL ENT to select to return to the run mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |