| 数据搜索系统,热门电子元器件搜索 |
|
300-R010-45G 数据表(PDF) 12 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
300-R010-45G 数据表(HTML) 12 Page - Magnetrol International, Inc. |
|
12 / 36 page ![]() MODEL 300/301 PRE-CONFIGURATION WORKSHEET 12 This page is designed to be a worksheet where all the sys- tem configuration data can be written down prior to entering them into the unit. The system configuration is much faster once all the data is known. This page can then be used for future reference after the unit has been configured. System configuration of the Model 300/301 is easily accom- plished by inputting the following values as they relate to your specific application: Level Applications Volume & Level Applications Flow & Level Applications Level units: Level units: Level units: Range: Volume units: Flow units: Span: Vessel type: Primary flow element: Vessel dimension: Reference distance: Range: Maximum head: Span: Low flow cutoff: Units: A selection for level units is required regardless of whether level will be the primary measurement. This is because the Model 300/301 calculates volume and flow from the level that is measured in the vessel, flume, or weir. One of the four level units shown on page 13 must be selected. Volume or flow units must also be selected if the Level Only mode is not being used. Range: Range is defined as the distance from the face of the ultrasonic transducer to the bottom of the level span. This usually is the distance from the face of the transducer to the bottom of the vessel. The maximum range for the Model 300/301 is 30' (9.1m). Span: Span is the distance from the bottom of the level measurement to the top. The maximum span is the range minus the dead band (18") of the ultrasonic transducer. The maximum span for the 300/301 is 28.5' (8.7m). Vessel Type: The Volume & Level mode will require one of the nine vessel types shown on page 13 to be selected. Equations to calculate volume from level are stored in the software. If the application has a vessel type that is not list- ed, then a custom table will need to be built using either a lin- ear or spline curve. Vessel Dimensions: Dimensional data will vary depending on which vessel type is selected. See pages 18 & 19 for more information. Primary Flow Element: The Flow & Level mode will require selection of one of the many flow elements to be selected that are shown on page 14. Equations to calculate flow from level are stored in the software. If the application has a flow element that is not listed, then a custom table will need to be built using either a linear or spline curve. Reference Distance: The reference distance is the open channel flow equivalent to the range. See above. Maximum Head: Maximum head is the open channel flow equivalent to the span. See above. Low Flow Cutoff: The low flow cutoff will force a zero flow value when the level is at or below this point. Model 300 Air Liquid Dead zone Range Span |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |