| 数据搜索系统,热门电子元器件搜索 |
|
804-R010-330 数据表(PDF) 21 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
804-R010-330 数据表(HTML) 21 Page - Magnetrol International, Inc. |
|
21 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 18 2.5.9 Advanced Configuration Menu This menu is used to set the non-control parameters of the Sentinel II. Follow this step-by-step procedure to use this menu. It is assumed that you are starting from the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Int’l x.x level units Normal operation This is the RUN mode. Run/Adv Config Adv Config > to select Access the Adv Config menu Use the arrow keys to scroll down until the display reads Adv Config. Run/Adv Config/ Damping Damping (1–60) 6 Set the output damping Set a damping factor to the 4–20 mA output to decrease the effect of turbulence. Enter the number of seconds. Run/Adv Config/ Damping Enter password Accept the data entered The Enter password display will not appear if a password has been entered anywhere else in the general program menu. Use the numeric keys to enter your password. Run/Adv Config/ Default Display Default Display Level Set the display for the run mode Set the display variable for the RUN mode. Run/Adv Config/ Change Password Change Password > to select Change the unit’s password Press ENT only if you want to change the password; press the down arrow to skip. Enter the current system password; press ENT. Then enter the new password; press ENT. Enter the new password again; press ENT. Run/Adv Config/ Adjust Loop Pts. Adjust loop pts. Calibrate the 4–20 mA output Allows matching of the actual 4–20 mA output with the displayed value from the measuring circuit. Adjustment is factory set and typically will not need to be readjusted. Run/Adv Config/ Adjust Loop Pts. 3.5 mA Offset xxx Set the 3.5 mA end point Use a DMM to measure the actual output current, increase or decrease the xxx value until DMM reads 3.5 mA. Press ENT. Run/Adv Config/ Adjust Loop Pts. 22 mA Offset xxx Set the 22 mA end point Use a DMM to measure the actual output current, increase or decrease the xxx value until DMM reads 22 mA. Press ENT. Press DOWN arrow. Run/Adv Config Previous Menu > to select Press DEL two times to return to the RUN mode. Run Magnetrol Int’l x.x level units Normal operation This is the RUN mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |