| 数据搜索系统,热门电子元器件搜索 |
|
804-R010-330 数据表(PDF) 22 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
804-R010-330 数据表(HTML) 22 Page - Magnetrol International, Inc. |
|
22 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 19 2.5.10 Diagnostics Menu This menu is used to offer the technician a method of testing the unit’s functionality. It also provides useful information for troubleshooting purposes. Follow this step-by-step procedure to use this menu. It is assumed that you are starting from the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Int’l x.x level units Normal operation This is the RUN mode. Run/Diagnostics Diagnostics > to select Access the Diagnostics menu Press the arrow keys to scroll down until the display reads Diagnostics. Run/Diagnostics/ Test Relay Test Relays > to select Test the relay outputs menu This menu allows you to energize/de-energize each output individually. Run/Diagnostics/ Test Relay Enter Password Accept the data entered Enter a number between 1 and 4. Use the arrow keys to toggle between Energize and De-energize. Run/Diagnostics/ Test Relay Select Relay ~ Set the relay to test Set the display variable for the RUN mode. Run/Diagnostics/ Test 4–20 mA Loop Test 4–20 mA Loop > to select Test the 4–20 mA output Press ENT twice. Enter the value of the desired output current. Press ENT. The 4–20 mA output is now at the desired loop current. Press ENT when finished. Run/Diagnostics/ Signal Values Signal Values > to select Access the Signal Values menu View actual signal readings from the electronics, probe, and preamplifier. Run/Diagnostics/ Signal Values CCO Int Cap x.xx uS Check the function of the internal oscillator This test compares the probe’s capacitance on the probe and displaying it as a function of the oscillator. Run/Diagnostics/ Signal Values CCO Open Probe x.xx uS Check the connection between the preamplifier and the probe This test compares the probe’s capacitance on the probe and displaying it as a function of the oscillator. Run/Diagnostics/ Signal Values CCO Probe x.xx uS Measure the probe’s capacitance in the application This test is measuring the actual capacitance on the probe and displaying it as a function of the oscillator. Run/Diagnostics/ Signal Values Previous Menu > to select Press ENT. Run/Diagnostics/ View Version # View Version # x.xx View the software revision # Displays the version number of Sentinel II software which is installed. Run/Diagnostics Previous Menu > to select Press DEL two times to return to the RUN mode. Run Magnetrol Int’l x.x level units Normal operation The RUN mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |