17 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 14 2.5.6 Measured Value Menu (In the charts that follow, this symbol, >, refers to .) The Measured Value menu is used to display current values being measured by the Sentinel II (refer to page 15 for the overall menu layout). Follow this step-by-step procedure to use this menu. It is assumed that you are starting from the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Int’l Normal operation This is the RUN MODE x.x level units Run/Measured Values Measured Values Access “Measured Values” menu > to select Run/Measured Values/ Level Display the process level Level units is the unit of measure selected Level x.x level units under SYSTEM CONFIG. Run/Measured Values/ Loop Display the loop current If the 4–20 mA output has not been Loop x.x mA programmed, this display will be 4.0 mA. Run/Measured Values/ Previous menu Press ENT to move up one level in the program to Measured Values; or press DEL twice to Previous Menu > to select return to the RUN MODE. Run Magnetrol Int’l This is the RUN mode. level/level units 2.5.7 System Configuration Menu This System Configuration menu is used to select the measurement units and to calibrate the probe for a particular application. Follow this step-by-step procedure to use this menu. It is assumed that you are starting from the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Intl Normal operation This is the RUN MODE x.x level units Run/System Config Run/System Config/ Access the System Config menu Use the arrow keys to scroll down until the >to select display reads “System Config”. Run/System Config/ Level Units Select the unit of measure for Use the arrow keys to select your option. Level Units calibration and display. The “Enter Password” display will not appear Run/System Config/ Enter password Accept the data entered if you have entered the password anywhere Level units else in the general program menu. Use the numeric keys to type in your password. Run/System Config/ Probe Calibrate Access the “Probe Calibrate” Read the following section before continuing. Probe Calibrate >to select NOTE: A minimum level change (2% of span) is required; however, a greater differential will improve accuracy. Two calibration points will be entered: Cal Pt. #1 (LO) is the lower point; Cal Pt. #2 (HI) is the upper point. They may be entered in any order. If it is easier to raise the level in your vessel, set “Cal Pt. #1 (LO)” first; raise the level a minimum of 2%, then set Cal Pt. #2 (HI)”. If it is easier to lower the level in your vessel, then set “Cal Pt. #2 (HI)” first; lower the level a mini- mum of 2%, then set “Cal Pt. #1 (LO)”. These calibration points do not have to correspond with the 4–20 mA output settings or any discrete out- put set point; they are two arbitrary points along the length of the probe. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |