6 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 3 Tanks/Silos with Non-Conductive Materials of Construction With plastic, concrete, wood, or any other non-conductive walled vessel, the reference electrode (mentioned in the Principle of Operation section on page 1) needs clarifica- tion. Most commonly, this electrode will be in the form of a concentric ground tube (for example, a stilling well). In questionable circumstances, consult the factory. In all cases, a good electrical connection must be made between the ground surface and the probe housing. NOTE: These comments also apply to glass-lined, metal walled tanks. Caution: When an insulated probe is used in a hazardous and/or abrasive medium, the probe should be inspected annually for nicks, cuts, or abrasions, which may ruin the integrity of the insulation. In the event that wear is found, replace the probe or consult the factory for further instructions. This procedure is critical in vessels containing hazardous media. 2.2 Mounting Probes should be mounted vertically and such that the probe rod is at least 2" (50 mm) below the lowest desired level control point with conductive materials; or, 4" (100 mm) below the lowest desired level control point in non-conductive materials. Refer to Figure 1. 2.2.1 Mounting Procedure Kotron Sentinel II Transmitters with standard probes up to and including 12" (305 mm) in length are shipped pre- assembled. Units with standard probes over 12" (305 mm) in length are shipped unassembled to avoid damage during transit; and must be assembled before mounting. Follow the proper mounting procedure for specific unit. NOTE: Before beginning mounting procedures, ensure that the power source to the unit is off. After installing the probe on the tank, and before wiring the electronics to the probe, it is beneficial to perform a probe resistance check to verify the integrity of the probe. The resistance of an insulated probe in conductive liquid (or a bare probe in non-conductive media), when measured between the probe screw terminal and the probe mounting nut with an ohmmeter set to its 20 megohm scale, should be INFINITE. 2.2.2 Integral Mount with Standard Rigid Probe 1. Thread probe into mounting bushing on tank. 2. Tighten securely—being certain that the wrench is applied only to the lower probe nut. Figure 1 Mounting nut Tank mounting bushing Actuation point in conductive media 2" |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |