86 / 253 page ![]() WM8321 Production Data w PD, February 2012, Rev 4.0 86 ADDRESS BIT LABEL DEFAULT DESCRIPTION 9:0 LDOn_UV_S TS 0 LDOn Undervoltage Status 0 = Normal 1 = Undervoltage Notes: 1. n is a number between 1 and 10 that identifies the individual LDO Regulator (LDO1 - 10). 2. m is a number between 1 and 4 that identifies the individual DC-DC Converter (DC-DC1 - 4). Table 38 DC Converter and LDO Regulator Status 15.12 POWER MANAGEMENT INTERRUPTS Undervoltage monitoring is provided on all DC-DC Converters and LDO Regulators, as described in Section 15.10. The associated interrupt flags indicate an undervoltage condition in each individual DC-DC Converter or LDO Regulator. Each of these secondary interrupts triggers a primary Undervoltage Interrupt, UV_INT (see Section 23). This can be masked by setting the mask bit(s) as described in Table 39. Current monitoring is provided on DC-DC1 and DC-DC2, as described in Section 15.10. The interrupt flags HC_DC1_EINT and HC_DC2_EINT indicate a high current condition in DC-DC1 and DC-DC2 respectively. Each of these secondary interrupts triggers a primary High Current Interrupt, HC_INT (see Section 23). This can be masked by setting the mask bit(s) as described in Table 39. The high current thresholds are programmable; these are set by DC1_HC_THR and DC2_HC_THR for DC-DC1 and DC-DC2 respectively. See Section 15.11.2 for details of these register fields. Note that these functions are for current monitoring; they do not equate to the DC-DC Converter maximum current limit. ADDRESS BIT LABEL DESCRIPTION R16403 (4013h) Interrupt Status 3 9:0 UV_LDOn_EINT LDOn Undervoltage interrupt (Rising Edge triggered) Note: Cleared when a ‘1’ is written. R16404 (4014h) Interrupt Status 4 9 HC_DC2_EINT DC-DC2 High current interrupt (Rising Edge triggered) Note: Cleared when a ‘1’ is written. 8 HC_DC1_EINT DC-DC1 High current interrupt (Rising Edge triggered) Note: Cleared when a ‘1’ is written. 3:0 UV_DCm_EINT DC-DCm Undervoltage interrupt (Rising Edge triggered) Note: Cleared when a ‘1’ is written. R16411 (401Bh) Interrupt Status 3 Mask 9:0 IM_UV_LDOn_EINT Interrupt mask. 0 = Do not mask interrupt. 1 = Mask interrupt. Default value is 1 (masked) R16412 (401Ch) Interrupt Status 4 Mask 9 IM_HC_DC2_EINT Interrupt mask. 0 = Do not mask interrupt. 1 = Mask interrupt. Default value is 1 (masked) 8 IM_HC_DC1_EINT Interrupt mask. 0 = Do not mask interrupt. 1 = Mask interrupt. Default value is 1 (masked) 3:0 IM_UV_DCm_EINT Interrupt mask. 0 = Do not mask interrupt. 1 = Mask interrupt. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |