| 数据搜索系统,热门电子元器件搜索 |
|
CS1630-FSZ 数据表(PDF) 22 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS1630-FSZ 数据表(HTML) 22 Page - Cirrus Logic |
|
22 / 56 page ![]() CS1630/31 22 DS954F2 5.10.2 PLC Program Mode Characters In order to program the CS1630/31, a set of encoded characters is built from specific phase-cut waveform patterns. Figure 24 illustrates the phase-cut waveform encoding recognized by the CS1630/31 power line calibration system. As shown in Table 1, six characters are formed using the special character and two-bit encoded data. 5.10.3 Calibration Mode Operation Code The CS1630/31 power line calibration system requires a start and stop operation code to activate and deactivate power line calibration mode. Once in the power line calibration mode, operation codes (OPCODE) will be used to program specific addresses using the OPCODE listed in Table 2. The LED light flashes seven times to indicate a command error. The LED flashes two times when OTP registers are programmed successfully and four times when programming is unsuccessful. Figure 25 illustrates an example of a power line calibration mode command sequence and the cut- waveform pattern. Character Code Notes Start Char (SC)00(SC) PLC Program Start Character(1) Stop Char (SC)11(SC) PLC Program Stop Character(1) Duo-bit ‘00’ 00 2-bit Data [00] Duo-bit ‘01’ 01 2-bit Data [01] Duo-bit ‘10’ 10 2-bit Data [10] Duo bit ‘11’ 11 2-bit Data [11] Note: (1) A Special Character (SC) must precede and follow the Duo-bit. Table 1. Power Line Calibration Characters 90° Special Char ‘11’ 146° ‘01’ 62° ‘10’ 118° ‘00’ 34° 90° 146° 90° PLC Stop Char 90° 34° 90° PLC Start Char Figure 24. Power Line Calibration Mode Character Waveforms PLC Start Character Addr Bcast & Simple Code 00 PLC Operation Code (4-bit) 0000 Odd Parity & Don’t Care 10 PLC Stop Character Before Transmit After Transmit 135° 135° 135° 135° 90° 34° 90° 90° 146° 90° 34° 34° 118° 34° Figure 25. Power Line Calibration Mode Example Calibration Command Sequence Start Char [(SC)00(SC)] Addr Bcast & Simple Code [1 Duo-bit] OPCODE [2 Duo-bits] Odd Parity & Don’t Care [1 Duo-bit] Stop Char [(SC)11(SC)] Name OPCODE Description NOP 0000 No Operation INIT_PROG_MODE 0001 Initialize program mode(1) I2C_WRITE 0010 Perform a generic I2C write 0011 Reserved BURN_OTP 0100 Initiate an OTP write cycle(3) STR1_OFFSET 0101 Write String 1 offset(2) STR2_OFFSET 0110 Write String 2 offset(2) WRITE_CRC 0111 Write CRC value END_PROG_MODE 1000 Disable programming mode WRITE_DIM 1001 Sets PLC dim value Notes: (1) Allows other commands to program the device under test. (2) Range of Offset tolerance is ±15%. (3) The light is flashed to indicate pass or fail. Table 2. Power Line Calibration Operation Code |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |