25 / 56 page ![]() CS1630/31 DS954F2 25 To perform a single shadow register write, a write to the Control Port must be used to set up the shadow register address and the BLK/SGL configuration bit (indicating a single write operation). To initiate a single write operation, a Start condition followed by a slave address of 0x20 (7 MSB device address = ‘0010000’ and the LSB R/W = ‘0’ for a write operation) is sent at the start of the message. The most significant bit of the second byte is cleared to ‘0’ to indicate a single byte write. The remaining 7 bits of the second byte represent the shadow register address of the write operation. After receiving the Acknowledge from the Control Port, the master should terminate the message by sending a Stop condition. The protocol for a single write operation is shown as the top frame in Figure 29. To initiate a block write operation, a Start condition followed by a slave address of 0x20 (7 MSB device address = ‘0010000’and the LSB R/W = ‘0’ for a write operation) is sent at the start of the message. The MSB of the second byte is set to ‘1’ to indicate a block write. The remaining 7 bits of the second byte represent the starting shadow register address of the write operation. The slave continues to send data bytes until the master sends a Stop condition after receiving the Acknowledge, signifying the end of the block write message. The protocol for a block write operation is illustrated by the bottom frame in Figure 29. Block writes will wrap around from shadow register address 127 to 0 if a Stop condition is not received. 5.11.5 Customer I2C Lockout The CS1630/31 provides a mechanism that locks or disables the I2C control port. This feature provides security against potential access to proprietary register settings and OTP memory (color compensation) through the I2C control port. To enable the lockout feature, the LOCKOUT bit is set to ‘1’ in the Config0 register (see "Configuration 0 (Config0) – Address 0" on page 29) and setting a 32-bit Lockout Key in registers LOCK3, LOCK2, LOCK1, and LOCK0 (at register address 0x01 to 0x04). The value of the Lockout Key is user programmable and stored in OTP memory (see "Lockout Key (LOCK0, LOCK1, LOCK2, LOCK3) – Address 1 - 4" on page 29). To unlock the Control Port, the proper programmed Lockout Key is written to the 32-bit Lockout Key shadow registers LOCK3, LOCK2, LOCK1, and LOCK0. The Lockout Key must be written in ascending address order for the lockout to be disabled. The MODE bit in register Config0 is set to ‘1’, the Color Polynomial Coefficient registers P10_MSB, P10_LSB, P01_MSB, and P01_LSB (at register address 0x09, 0x0A, 0x0F, and 0x10) are appended to the Lockout Key to increase security. If the wrong Lockout Key is written to the shadow resisters when attempting to disable the lockout feature, the part cannot be unlocked until a reset cycle occurs. In lockout mode, the Control Port disables the following operations through the I2C communication port: •I2C read operations from OTP shadow registers (value of 0x0 will be read through control port) •I2C write operations to lockout enabled or key shadow registers (including read operations through PLC) • Direct OTP memory read or write (including reads/writes through PLC) Write operations to either OTP or test space (except OTP Lockout Key) are allowed in lockout mode. 5.12 OTP Memory At startup, the contents of the OTP memory are read into shadow registers that make up a register file. Access to the OTP memory values is accomplished by reading and writing to the OTP corresponding address locations in that register file. To program the part, each unprogrammed address location must be filled with an appropriate value. Next, a CRC is calculated corresponding to the OTP space that is being programmed. Lastly, two special registers are written to initiate a burn/program cycle. Figure 29. Frame Formats for Write Operation 0 A 0 S A Device Address (7-bit) Register Address (7-bit) ‘0’ = Single ‘0’ = Write Start Condition Stop Condition Data Transferred (2 Bytes and Acknowledge) Slave Address (1 Byte and Acknowledge) P A Data ‘A’ = Acknowledge (SDA Low) ‘1’ = Block S A Device Address (7-Bit) Register Address (7-Bit) Data … ... From Slave to Master From Master to Slave ‘0’ = Write Start Condition Stop Condition ‘A’ = Acknowledge (SDA Low) Data Transferred (n Bytes and Acknowledge) 0 A 1 A Slave Address (1 Byte and Acknowledge) P A Data |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |