45 / 108 page ![]() ADE9078 Data Sheet Rev. 0 | Page 44 of 107 To accumulate energy over a defined number of samples, use the following settings: • Set the configuration register as follows: • EGY_LD_ACCUM = 1 • EGY_TMR_MODE = 0 • RD_RST_EN = 0 • EGY_PWR_EN = 1 • EGY_TIME to the desired number of samples • For the output, the xHR_HI register has enough resolution for most applications. To maintain perfect synchronization with the CF pulse output, the xHR_LO must be read as well because it is cleared at every EGYRDY cycle. • Set the maximum time before reading xHR_HI to prevent overflow with full-scale inputs to 26.4 sec. Digital to Frequency Conversion—CFx Output Many electricity meters are required to provide a pulse output that is proportional to the energy being accumulated, with a given pulse per kWh meter constant. The ADE9078 includes four pulse outputs that are proportional to the energy accumulation in the CF1 through CF4 output pins. A block diagram of the CFx pulse generation is shown in Figure 65. fDSP RESERVED xWATT xVAR xVA xFVAR RESERVED xWATT CFxSEL[2:0] 100 011 000 001 010 101 110 xWATT 111 0 0 1 TERMSELX[0] PHASE A 0 0 1 TERMSELX[1] PHASE B 0 0 1 TERMSELx[2] + + + CFxSEL[2:0] WTHR CFx_LT CF_LTMR[18:0] CFxDIS 4.096MHz DIGITAL TO FREQUENCY 512 CFxDEN CF_ACC_CLR 0 1 1 CFx PIN PULSE WIDTH CONFIG ADE9078 CFx BITS PHASE C VARTHR VATHR WTHR VARTHR VATHR WTHR WTHR 100 011 000 001 010 101 110 111 ÷ Figure 65. Digital to Frequency Conversion for CFx Table 20. CFx Active Low Pulse Width and Duty Cycle Based on CFx_LT and CF_LTMR CFx_LT Active Low Pulse Width for Low Frequencies (ms) Active Low Pulse Width for High Frequencies when CFxDEN is Even Active Low Pulse Width for High Frequencies when CFxDEN is Odd Behavior when Entering No Load 0 80 50% (1 + 1/CFxDEN) × 50% If CFx is low, finish current pulse, return high. 1 CF_LTMR × 6/CLKIN × 1000 50% (1 + 1/CFxDEN) × 50% If CFx is low, keep CFx low until the no load state is finished. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |