10 / 42 page ![]() Multiple-Output Regulator for Automotive LCD Displays A8603 10 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com CHARACTERISTIC PERFORMANCE VIN (power supply) EN (external enable) BIAS (IC internal supply) FAULT (pull-up to VIN) <1 ms I2C commands Internal Enable AVDD VCOM VGL VGH Startup Timeout (10 to 99 ms) tSU_TO t1 t2 t3 t4 90% t≥0 t1...t4 = startup delay (0 to 25.5 ms) AB C D I2C Read/Write allowed at any time; however, user must not make arbitrary changes in regulator target voltages; otherwise, it may interfere with startup process or trip OVP/UVP. Startup Timing Diagram Sequence of events: A:System controller brings EN = H to enable the A8603, provided that VIN is above UVLO level. B:After A8603 performs a Power-On Reset (POR), it pulls down FAULT flag to signal that it is ready for I2C commands. (*) C:System controller detected FAULT = L and sends in I2C command to clear POR status bit. This resets FAULT to H (unless there were other faults detected). D:After Programming the A8603 registers, system controller sets the regulator_internal_enable bit to 1 to turn on all output regulators. (*) The delay time between EN = H and FAULT = L depends mainly on how fast the external BIAS capacitor can be charged up. For example, charging 1 µF at 5 mA from 0 to 2.8 V takes ~0.6 ms. Therefore, a 1 ms delay time is sufficient. • Each regulator has a programmable Startup Delay timer. Each timer has a resolution of 0.1 ms and a maximum duration of 25.5 ms. • VCOM cannot start before AVDD (because internally the VCOM regulator takes its power from AVDD output) • VGH cannot start before VGL has reached 90% of its target voltage • There is no dependency between {t1, t2} and {t3, t4}. That means VGL/VGH can start before or after AVDD/VCOM • If any regulator output failed to reach 90% target after the Startup Timeout period (default 50 ms, starting from Internal Enable = H), the FAULT pin will be pulled low and all outputs are shut down in an orderly manner. The IC will then retry after a Cool Down period. Notes on Startup Timing Diagram |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |