| 数据搜索系统,热门电子元器件搜索 |
|
A8603KESTR-R 数据表(PDF) 31 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
A8603KESTR-R 数据表(HTML) 31 Page - Allegro MicroSystems |
|
31 / 42 page ![]() Multiple-Output Regulator for Automotive LCD Displays A8603 31 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Fault Monitoring The fault monitoring system prioritizes the fault in three different categories. Based on the severity of the fault, diagnostic algo- rithm handle the shutdown sequence of all regulators. FAULT1 (GROUP1) If any fault from the below list is detected, the A8603 halts operation and pulls the FAULT pin low. All regulators shut down in sequence. It then attempts to restart operation after a delay, tRESTART (default 100 ms). Internally, there is a fault counter that keeps tracks of how many times any fault has occurred. If the fault counter reaches its programmed limit (default 8), the A8603 is completely shutdown. A hardware reset (either by EN = L or VIN below UVLO) is then required before the A8603 can restart. Startup Fail Regulator output voltage fails to reach 90% of its target voltage within timeout period Regulator Undervoltage Regulator output voltages are below 80% of the target voltage. This signal is ignored during startup. Regulator Overvoltage Regulator output voltage are above 120% of the target voltage. This signal is ignored during startup. Regulator Overcurrent Regulator output currents are above the current limit threshold. This signal is ignored during startup. FSET Shorted FSET pin shorted to ground. IC moves to internal fixed 1 MHz oscillator. • Each regulator output is protected by its own independent overcurrent limit. When an output current exceeds its limit, the corresponding regulator goes in to overcurrent protection mode to protect itself from damage. If the overcurrent condition persists for 50 ms, all regulators are turned off following the normal shutdown sequence. • Each regulator output is protected by its own overvoltage fault detection. When an output voltage exceeds its limit, the corresponding regulator is turned off immediately. The other outputs then shut down following normal sequence. The same applies to undervoltage fault detection. • When FSET pin is shorted to ground, IC begins a shutdown sequence, at the switching frequency set by the internal 1 MHz oscillator. The FAULT pin is pulled low and the internal error counter is increased by 1. FAULT2 (GROUP2) When following faults are detected, the A8603 halts operation and pulls the FAULT pin low. All outputs are shut off immedi- ately. It then attempts to restart operation after a delay, tRESTART (default 100 ms). Internally, there is a fault counter that keeps tracks of how many times any fault has occurred. If the fault counter reaches its programmed limit (default 8), the A8603 is completely shut down. A hardware reset (either by EN = L or VIN below UVLO) is then required before the A8603 can restart. SW Overvoltage SW pin voltage exceeds SWOVP SW Overcurrent SW pin current exceeds ISWILIM2. Thermal Shutdown IC die temperature exceeds TTSD FAULT3 (GROUP3) When a supply undervoltage fault is detected, the A8603 shuts down immediately. All outputs are turned off without following the shutdown sequence. All digital states are erased. The FAULT flag will not be asserted. The device will not attempt to restart. VIN UVLO VIN (input supply) is below 2.8 V. BIAS UVLO VBIAS (internal rail) is below 2.6 V. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |