| 数据搜索系统,热门电子元器件搜索 |
|
A8603KESTR-R 数据表(PDF) 29 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
A8603KESTR-R 数据表(HTML) 29 Page - Allegro MicroSystems |
|
29 / 42 page ![]() Multiple-Output Regulator for Automotive LCD Displays A8603 29 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Pre-Output Fault Detection When EN = High and the A8603 output regulators are enabled through I2C command, a startup sequence is followed before the regulators are powered up. The sequence checks for extreme conditions and proceeds as described in Table 16. Step Number Step Description Step Description Fault Tripped? 1 Check VIN UVLO A8603 remains powered-down until VIN is above VUVLO. No 2 Power-up internal rail A8603 initializes. No 3 Check internal rail UVLO BIAS charges internal rail indefinitely, until VBIAS is above UVLO. No 4 Turn on AVDD Enable AVDD and check to see if output reaches >90% of target voltage within tSS(TO). Yes 5 Turn on VGL Enable VGL and check to see if output reaches >90% of target voltage within tSS(TO). Yes 6 Turn on VGH Enable VGH and check to see if output reaches >90% of target voltage within tSS(TO). Yes 7 Turn on VCOM Enable VCOM and check to see if output reaches >90% of target voltage within tSS(TO). Yes Table 16: Pre-Output Fault Detection Sequence General Fault Detection The faults described in Table 17 are continuously monitored, whether during startup, normal operation, or shutdown. Table 17: General Fault Detection Fault Description A8603 Response to Fault Fault Tripped? AVDD, VCOM,VGH or VGL 20% under target Shutdown using shutdown sequence. Fault counter increased by one, retry after tRESTART. Yes: FAULT set during tRESTART. AVDD, VCOM,VGH or VGL 20% over target Over target regulator rail shutdown immediately. Other regulator rails shutdown using shutdown sequence. Fault counter increase by one retry after tRESTART. Yes: FAULT set during tRESTART. Overcurrent limit for iAVDD, iVCOM, iVGH or iVGL Offending regulator rail goes into current fold-back or current limit. Shutdown using shutdown sequency after tOCP. Fault counter increase by one, retry after tRESTART. Yes: FAULT set during tRESTART. SW_OVP exceeded Shutdown all regulators immediately without using shutdown sequence. Fault counter increased by one, retry after tRESTART. Yes: FAULT set during tRESTART. External UVLO reached Shutdown all regulators immediately without using shutdown sequence. Fault counter reset to 0, retry after tRESTART. No Internal (Bias) UVLO Shutdown all regulators immediately without using shutdown sequence. Fault counter reset to 0, retry after tRESTART. No TSD exceeded Shutdown all regulators immediately without using shutdown sequence. Fault counter increase by one, retry after tRESTART. Yes: FAULT set during tRESTART. SWILIM2 (150% of cycle-by-cycle limit) exceeded Shutdown all regulators immediately without using shutdown sequence. Fault counter increased by one, retry after tRESTART. Yes: FAULT set during tRESTART. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |