11 / 42 page ![]() Multiple-Output Regulator for Automotive LCD Displays A8603 11 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com AB CD VIN (power supply) EN (external enable) BIAS (IC internal supply) FAULT (pull-up to VIN) Internal Enable AVDD VCOM VGL VGH t5 t6 t7 t≥0 t8 30% tSD_TO Shutdown Timeout (50 ms) Shutdown Timing Diagram Sequence of events: A:System controller brings EN pin to Low for >2 µs to initiate a “Hardware Shutdown.” The IC responds by pulling Internal Enable to Low. B:The A8603 shuts down all output regulators in sequence, according to their shutdown delay times. All registers will be restored to power-up defaults at the end of a Hardware Shutdown. This does not apply to a Software Shutdown when user programs INT_EN = L. C:After the last regulator has shut down, the A8603 resets all internal registers to their power-on defaults, sets the HARD_RESET status bit to 1, and pulls FAULT pin to Low. The A8603 is now ready to accept new I2C commands. D:The A8603 is powered down only if EN = L after shutdown has completed. • Each regulator has a programmable Shutdown Delay timer. Each timer has a resolution of 0.1 ms and a maximum duration of 25.5 ms. • AVDD can only be turned off after VCOM is turned off (t5 = 0 is allowed) • VGL can only be turned off after VGH drops below 30%, even through t7 = 0 is allowed. • There is no dependency between {t5, t6} and {t7, t8} • Once a shutdown is in progress, both external Enable and Internal EN are ignored until shutdown is completed. • All output discharge times are based on external capacitance and internal pull-down resistance (250 Ω for AVDD and VCOM, 500 Ω for VGH and VGL). The external DC load is assumed to be negligible. • If any of the regulator output does not decay to below 10% (30% for VGL and VGH) of target voltage after 50 ms time-out period, starting from beginning of shutdown, it is ignored and then the IC is allowed to power down. Notes on Shutdown Timing Diagram |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |