| 数据搜索系统,热门电子元器件搜索 |
|
LTM4686BEVPBF 数据表(PDF) 104 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BEVPBF 数据表(HTML) 104 Page - Analog Devices |
|
104 / 130 page ![]() LTM4686B 104 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS MFR_OT_FAULT_RESPONSE The MFR_OT_FAULT_RESPONSE command byte instructs the device on what action to take in response to an internal overtemperature fault. The data byte is in the format given in Table 27. The LTM4686B also: • Sets the MFR bit in the STATUS_WORD, and • Sets the Overtemperature Fault bit in the STATUS_MFR_SPECIFIC command • Notifies the host by asserting ALERT pin, unless masked. This command has one data byte. Table 27. Data Byte Contents MFR_OT_FAULT_RESPONSE BITS DESCRIPTION VALUE MEANING 7:6 Response For all values of bits [7:6], the LTM4686B: • Sets the corresponding fault bit in the status commands and • Notifies the host by asserting ALERT pin, unless masked. The fault bit, once set, is cleared only when one or more of the following events occurs: • The device receives a CLEAR_FAULTS command • The output is commanded through the RUNn pin, the OPERATION command, or the combined action of the RUNn pin and OPERATION command, to turn off and then to turn back on, or • Bias power is removed and reapplied to the LTM4686B 00 Not supported. Writing this value will generate a CML fault. 01 Not supported. Writing this value will generate a CML fault 10 The device shuts down immediately (disables the output) and responds according to the retry setting in bits [5:3]. 11 The device’s output is disabled while the fault is present. Operation resumes and the output is enabled when the fault condition no longer exists. 5:3 Retry Setting 000 The unit does not attempt to restart. The output remains disabled until the fault is cleared. 001–111 Not supported. Writing this value will generate CML fault. 2:0 Delay Time XXX Not supported. Value ignored Fault Responses Power Stage Temperature COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE OT_FAULT_ RESPONSE 0x50 Action to be taken by the device when a power stage overtemperature fault is detected, R/W Byte Y Reg Y 0x80 UT_FAULT_ RESPONSE 0x54 Action to be taken by the device when a power stage undertemperature fault is detected. R/W Byte Y Reg Y 0x80 OT_FAULT_RESPONSE The OT_FAULT_RESPONSE command instructs the device on what action to take in response to a power stage over- temperature fault. The data byte is in the format given in Table 28. The device also: • Sets the TEMPERATURE bit in the STATUS_BYTE • Sets the Overtemperature Fault bit in the STATUS_TEMPERATURE command, and • Notifies the host by asserting ALERT pin, unless masked. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |