58 / 84 page ![]() 92FD54AI-58 2006-01-27 TMP92FD54AI 7) Auto Block Protect Auto Block Protect allows individual blocks to be protected from being written or erased. The table below shows the relationship between protection status and the rewrite operation. Table 4.4.2 Block protection status and the Rewrite operation Protection Status and Operation Executed Result of executed operation Execute Program on protected block Not programmed and automatically returns to Read Mode Execute Erase on protected block Not erased and automatically returns to Read Mode Execute Chip Erase when all blocks are protected Not erased and automatically returns to Read Mode Execute Chip Erase when any blocks are protected Only the unprotected blocks are erased. Upon completion, the flash memory automatically returns to Read mode Writing to the protect circuit is initiated by the address of the block to be protected in the sixth Bus Write cycle of the command sequence, and set data to “70H”. (see Figure 4.4.8) During automatic operation no other command sequence input can be accepted. To stop operation use a hardware reset. When it erases Auto Block Protect, use Auto Chip Erase & Unprotect command. (see Table 4.4.3) In this case it erases all Auto Block Protect and all blocks of the flash memory. 8) Verify Block Protect Verify Block Protect is used to check whether or not blocks are protected. Enter the address of the block you want to check in the fourth Bus Read cycle of the command sequence. At this time, specify an address where A3 = A6 = 0, A4 = 1, and read the selected block in units of long words. If the block is protected, the data returned will be 00000001H. Conversely, if the block is unprotected, the data returned will be 00000000H. To continue verifying the protection of other blocks, it is only necessary to repeating the fourth Bus Read cycle so as to read out data from each block. Change the block address as desired and read the data out in long words. To return to Flash Memory Read or any other command input after the Verify Block Protect has been completed, it is necessary to issue a Read/Reset command or a hardware reset. 9) Hardware Sequence flags (see Table 4.4.6) The status of automatic execution of operations on flash memory can be checked by inspecting the Hardware Sequence flags. During automatic operation data can be read out with the same timing as that of Read Mode. The flash memory automatically returns to Read Mode after automatic operation has finished. During automatic execution it is possible to monitor the operating status by inspecting the Hardware Sequence flags. After automatic operation has finished, the operating status can be confirmed by checking the read data to see that it matches the cell data. To inspect the Hardware Sequence flags during an Auto Program operation, specify the same address as the one which has been set by the rewrite routine (in which A0 = A1 = 0) at the same time as reading out the flag. Also, to inspect the Hardware Sequence flags during an Auto Erase operation, specify an address in which A0 = A1 = 0 at the same time as reading out the flag. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |