36 / 55 page ![]() Data Sheet ADE9103/ADE9112/ADE9113 APPLICATIONS INFORMATION analog.com Rev. A | 36 of 55 Power-Up Procedure for Systems with Multiple Devices That Use a Clock Signal Generated from a Microcontroller For polyphase energy meters in which the microcontroller gener- ates the clock signal used by all ADE9103/ADE9112/ADE9113 devices, the power-up procedure is as follows: 1. Supply VDD to the ADE9103/ADE9112/ADE9113 devices. To ensure that the ADE9103/ADE9112/ADE9113 devices start functioning correctly, the supply must reach 3.3 V − 10% in less than 16 ms from approximately a 2.5 V level. 2. Generate the clock signal from the microcontroller to all ADE9103/ADE9112/ADE9113 devices. 3. The DC-to-DC converters power up and supply the isolated side of the ADE9112/ADE9113 devices. The Σ-Δ modulators then become functional. This process takes approximately 62 ms to execute when the recommended capacitors on the VDDISO, LDO, and REFOUT pins described in Table 12 are used. After this time, the isolated sides of the ADE9112/ ADE9113 devices are fully functional. While the ADE9103 has no isolation and is entirely powered by VDD, the power-up timing remains the same. 4. Read the STATUS0 registers of the ADE9103/ADE9112/ ADE9113 devices until Bit 5 (RESET_DONE) is set to 1, indicating that the nonisolated side of the ADE9103/ADE9112/ ADE9113 devices is fully functional with default settings, which happens approximately 32 ms after the clock signal is provided. 5. Initialize the CONFIG0 register of the ADE9103/ADE9112/ ADE9113 devices with Bit 0 (CLKOUT_EN) cleared to 0 to avoid generating an unnecessary clock at the CLKOUT/DREA- DY pin. Select one ADE9112/ADE9113 device (Phase C, for example, ADE9112C/ADE9113C) and connect the CLKOUT/ DREADY pin to an external interrupt input and output pin of the microcontroller. 6. Execute a SYNC_SNAP = 0x02 broadcast to synchronize all the ADE9103/ADE9112/ADE9113 devices of the meter (see the Synchronizing Multiple ADE9103/ADE9112/ADE9113 Devices section for more information). 7. Execute a WR_LOCK = 0xD4 write broadcast to protect the configuration registers of all ADE9103/ADE9112/ADE9113 devi- ces. See the Protecting the Integrity of Configuration Registers section. Figure 46. Power-Up Procedure for Systems with Multiple ADE9112/ADE9113 Devices Clocked from a Microcontroller |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |