| 数据搜索系统,热门电子元器件搜索 |
|
PIC16F1507-E/SS. 数据表(PDF) 179 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC16F1507-E/SS. 数据表(HTML) 179 Page - Microchip Technology |
|
179 / 278 page ![]() 2011-2015 Microchip Technology Inc. DS40001586D-page 179 PIC16(L)F1507 FIGURE 22-2: TYPICAL CWG OPERATION WITH PWM1 (NO AUTO-SHUTDOWN) 22.5 Dead-Band Control Dead-band control provides for non-overlapping output signals to prevent shoot-through current in power switches. The CWG contains two 6-bit dead-band counters. One dead-band counter is used for the rising edge of the input source control. The other is used for the falling edge of the input source control. Dead band is timed by counting CWG clock periods from zero up to the value in the rising or falling dead- band counter registers. See CWGxDBR and CWGxDBF registers (Register 22-4 and Register 22-5, respectively). 22.6 Rising Edge Dead Band The rising edge dead-band delays the turn-on of the CWGxA output from when the CWGxB output is turned off. The rising edge dead-band time starts when the rising edge of the input source signal goes true. When this happens, the CWGxB output is immediately turned off and the rising edge dead-band delay time starts. When the rising edge dead-band delay time is reached, the CWGxA output is turned on. The CWGxDBR register sets the duration of the dead- band interval on the rising edge of the input source signal. This duration is from 0 to 64 counts of dead band. Dead band is always counted off the edge on the input source signal. A count of 0 (zero), indicates that no dead band is present. If the input source signal is not present for enough time for the count to be completed, no output will be seen on the respective output. 22.7 Falling Edge Dead Band The falling edge dead band delays the turn-on of the CWGxB output from when the CWGxA output is turned off. The falling edge dead-band time starts when the falling edge of the input source goes true. When this happens, the CWGxA output is immediately turned off and the falling edge dead-band delay time starts. When the falling edge dead-band delay time is reached, the CWGxB output is turned on. The CWGxDBF register sets the duration of the dead- band interval on the falling edge of the input source sig- nal. This duration is from 0 to 64 counts of dead band. Dead band is always counted off the edge on the input source signal. A count of 0 (zero), indicates that no dead band is present. If the input source signal is not present for enough time for the count to be completed, no output will be seen on the respective output. Refer to Figure 22-3 and Figure 22-4 for examples. cwg_clock PWM1 CWGxA CWGxB Rising Edge Dead Band Rising Edge Dead Band Rising Edge Dead Band Falling Edge Dead Band Falling Edge Dead Band |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |