5 / 55 page ![]() MAS281 5/55 or more faults in FT will cause a level 1 (machine error) interrupt request. Once a fault is set in FT, it may only be cleared via an XIO command. 1.3.5 TIMERS A AND B These are two 16-bit software controllable timers. Timer A is clocked by the TCLK input while Timer B is clocked by the internally generated TCLK/10. Timers A and B will generate interrupt levels 7 and 9, respectively, when their maximum counts of 65,536 are reached. 1.3.6 TRIGGER-GO COUNTER This 16-bit counter is clocked by the TGCLK input, is enabled during system initialisation, and may be reset but not stopped by software action. It is stopped, however, upon overflow or by assertion of the DTIMERN input. Upon overflow, the TGON discrete output goes low and stays low until the counter is reset by software. This counter is typically used as a system “watchdog" timer. 1.3.7 XIO COMMAND DECODE LOGIC This logic decodes all internally supported XlO commands and generates the control signals necessary to carry out the commanded action. An internal ready signal is generated upon command detection and is used by the EU state sequencer as previously discussed. Table 7b in Section 4.0 identifies the XlO commands which are internally supported by the MAS281. 1.3.8 MICROCODE CONTROL LOGIC Decode logic, which translates microcode received from the CU into control signals, is used both by the MAS281 and by the external system. 2.0 INTERFACE SIGNALS 2.1 PIN ASSIGNMENTS Figure 4 defines the pin assignment for the MAS281 module. See section 10.0 for full packaging and pin assignment information. All signals - with the exception of power, ground and ROMONLYN - are TTL compatible. In addition, each function is provided with Electrostatic Discharge (ESD) protection circuitry. Figure 5 depicts a typical system implementation using many of these signals. Throughout this data sheet, active low signals are denoted either by placing a bar over the signal name, or by following the signal name with an “N” suffix, e.g., DDN. If a signal has a dual function, both function names will be used separated by a “/”. The function name to the left of the “/” will be active high while the function to the right will be active low, again with an “N" suffix, e g., RD/WN. 1.2.2 MICROCODE ROM This is a 2k- (2048) word by 40-bits/word ROM which stores the microinstructions that implement the MIL-STD- 1750A instruction set. The address of the next microinstruction to be accessed is generated by the microsequencer. The accessed microinstruction is output to the M-bus and broadcast to the EU and IU. In addition to the microinstruction sequences corresponding to the MIL-STD-1750A instructions, the microcode ROM also stores sequences for performing initialisation, interrupt response, Hold response, instruction prefetch, built-intest (BIT), and BlFs. 1.2.3 INSTRUCTION MAPPING ROM This is a 512-word by 8-bits/word ROM which is used during microcode branches. 1.3 INTERRUPT UNIT (IU) The IU incorporates a pending interrupt register, a mask register, a priority encoder, a fault register, two interval timers (A and B), a trigger-go counter, XIO command decode logic, and microcode control logic. A brief description of these features follows: 1.3.1 PENDING INTERRUPT REGISTER (PL) This 16-bit register is used to capture and hold interrupts until they can be processed by software. Pl supports three dedicated external, six user-definable external, and seven dedicated internal interrupts. Interrupts are captured at the beginning of each machine cycle and are stored using a logic 1 to represent a pending interrupt. Anti-repeat logic is provided to prevent multiple captures of the same interrupt. 1.3.2 MASK REGISTER (MK) This 16-bit register is used to store the interrupt mask. Interrupts are masked by ANDing each mask bit with its corresponding Pl register bit. Interrupts which are masked will be captured in the Pl register but will not be acted on until unmasked. Interrupt level 0 can not be masked. A logic 0 in a given bit position indicates that the corresponding bit in the Pl register will be masked. 1.3.3 PRIORITY ENCODER This encoder generates an interrupt request to the CU whenever one or more unmasked interrupts are pending and enabled in the Pl and encodes the highest priority unmasked pending interrupt as a 4-bit vector. This vector is read by the EU over the AD bus during interrupt servicing in order to create the interrupt Linkage and Service pointers. 1.3.4 FAULT REGISTER This 16-bit register is used to capture and hold both internal and user implemented external faults. Faults are captured at the beginning of each machine cycle and are stored using positive logic, i e, a logic “1” represents a fault. Setting any one |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |